User manual

BEETLE /X plus User Manual 39
Total Current Consumption Of Interfaces
The total current consumption at 5V interfaces must not exceed 5A.
Each COM* = 300mA, in total 500mA
Each USB = 500mA, in total 2A
Each USB (HUB) = 500mA, in total 2A
TFT/LCD-Display
Max. 5A @ 5V
The total current consumption at 12V interfaces must not exceed 5A.
Each COM* = 600 mA, in total 900mA
Each USB = 1.5A, in total 2A
Each USB (HUB) = 1.5A, in total 2A
TFT/LCD-Display
Max. 5A @ 12V
The 24V PoweredUSB interface is provided for the operation of Retail
thermo printers. The peak load is accordingly designed.
Power loss of additionally implemented PCI- and PCIe- Controllers is
for thermic reasons - limited to 10W for each slot and all together to 20W.