INSTALLATION, OPERATIONS and MAINTENANCE INSTRUCTIONS W6010DE/F OWNERS MANUAL 60706-215
Read and understand all instructions in the manual before starting and operating the generator set. USING THIS MANUAL PROPER USE AND INSTALLATION Congratulations on your choice of a Winco generator set. You have selected a high-quality, precision-engineered generator set designed and tested to give you years of satisfactory portable service. . To get the best performance from your new engine generator set, it is important that you carefully read and follow the operating instructions in this manual.
This engine generator set has been designed and manufactured to allow safe, reliable performance. Poor maintenance, improper or careless use can result in potential deadly hazards; from electrical shock, exhaust gas asphyxiation, or fire. Please read all safety instructions carefully before installation or use. Keep these instructions handy for future reference. Take special note and follow all warnings on the unit labels and in the manuals. ANSI SAFETY DEFINITIONS b.
SPECIFICATIONS MODEL W6010DE/F Generator Surge Watts Continuous Watts Volts AMPs @ 240 Volts AMPs @ 120 Volts Engine Size Model Type Fuel CapacityFuel Consumption Starting System Muffler Stop System RESTRICTED USES 1. DO NOT remove from the base assembly. Removal of the generator from the base assembly or operating without the shock mounts installed may cause excessive vibration and damage to the engine generator set. 6000 5500 120/240 22.9 45.8 2.
Starting Electric Motors - Electric motors require much more current (amps) to start them than to run them. Some motors, particularly low cost split-phase motors, are very hard to start and require 5 to 7 times as much current to start them as to run them. Capacitor motors are easier to start and usually require 2 to 4 times as much current to start them as to run them. Repulsion Induction motors are the easiest to start and usually require 1 1/2 to 2 1/2 times as much to start them as to run them.
A twelve volt battery, group U1 rated at 300 CCA or larger is recommended for this electric start engine generator set. Follow the battery manufacturers recommendations for servicing and charging prior to use. Connect the battery to the electric start system using the cables provided. CAUTION: EQUIPMENT DAMAGE These electric start engines are NEGATIVE GROUND. Use extreme caution when connecting the battery. Connect the NEGATIVE battery terminal to GROUND.
2. Electric Starting - Always keep the battery charged, but especially during cold weather operation. a. Turn on the fuel supply and prime the fuel line up to the injector pump. b. Operate the key switch. Position # will turn on the fuel solenoid and position #II will engage the starter. The switch is spring loaded to the #I position, so when you release the key the switch returns to this position. c. The engine will start and come up to operating speed. d.
recheck the rating of the generator set. Be sure it can handle the intended load and is compatible with the voltage, phase, and current ratings. CONNECTING THE LOADS Applying The Load Allow the engine to warm up for two or three minutes before applying any load. This will allow the engine to reach normal operating temperature and oil to circulate throughout the engine.
amperage is available from the generator set. Some circuit breakers may still have to be turned off to prevent an overload on the generator during the initial start up. See the nameplate on your generator for the amperage capabilities of your unit. CAUTION: EQUIPMENT DAMAGE Failure to properly limit and balance the load applied to the generator will cause the generator to produce low voltage and may damage the engine generator set.
Voltage too low *Engine speed is too low. *Generator overloaded. *Defective stator. *Defective rotor (field). —————————————————————————— Circuit Breaker Trips *Defective load. *Defective receptacle. —————————————————————————— Voltage too high *Engine speed is too high. —————————————————————————— Generator overheating *Overloaded. *Insufficient ventilation. —————————————————————————— No output voltage *Short in load (disconnect). 1.
60706-215 Page 9 W6010DE/F WIRING DIAGRAM
WINCO, Incorporated warrants to the original purchaser for 24 months that goods manufactured or supplied by it will be free from defects in workmanship and material, provided such goods are installed, operated and maintained in accordance with Winco written instructions. WINCO’s sole liability, and Purchaser’s sole remedy for a failure under this warranty, shall be limited to the repair of the product.