User Manual

Malfunctions Possible causes Remedy Chap.
20
At low
temperatures:
If equipped with a
stop solenoid or
automatic electri-
cal shutdown sys-
tem (additional
equipment)
6.2.
Engine fires but
does not run.
Automatic
electrical shut-off
device
(optional extra)
6.3.
Starter motor does
not operate or en-
gine does not turn
over.
Starting speed below 400 min
-1
-Viscosity of oil too high.
-Battery charge too low.
Solenoid faulty and/or fault in
the electrical system.
Speed control lever not moved
far enough towards „START“.
Equipment not disengaged.
Fuel filter blocked.
One of the automatic shut-
down's monitoring elements
has initiated a stop signal.
(See also Chapter 6.4.)
Fault in the electrical system:
-Battery and/or other cables
incorrectly connected up.
-Cable connections loose and/or
oxidised.
-Battery faulty and/or flat.
-Starter motor faulty.
-Faulty relays, monitoring
element.
Change lubricating oil and add
oil of the correct viscosity class.
Check the battery, if necessary
contact a service station.
See workshop manual.
Move lever to „START“ position.
Disengage engine from equip-
ment if possible.
Renew fuel filter.
Localise the monitoring element
responsible and clear the fault,
or contact a
HATZ service station.
Check electrical system and its
component. See also the work-
shop manual.
5.3.2.
4.1.1.
7.
4.2.1.
5.4.1.
7.