Dimensions Guide
Subject to change without notice. Published in U.S.A. 5006168-CTG-C-1015
Copyright © 2015 by Johnson Controls, Inc. All rights reserved. Supersedes: 5006168-CTG-B-0915
York International Corp.
5005 York Drive
Norman, OK 73069
WIRING DIAGRAM
BLOWER
MOTOR
RC
XFORMER
BLK
RED/WHT
RED/
WHT
PRP
PRP
BLU/WHT
BLU/WHT
GRN FAN
BRN
WHT
ORG
RED 24V (HOT)
BLU 24V (COM)
ELECTRIC HEAT
1st STAGE
AUXILIARY HEAT
2nd STAGE
BRN
GRN
PRP
BLK
H M L
EQUIPMENT
GROUND
BLK
RED/WHT
{
208-240 VAC 60HZ
1 PHASE SUPPLY
24V
240V
COM
208V
XFORMER
BLOWER
MOTOR
N.O.
N.C.
COM
BLOWER
CONTROL
RELAY
RED
GRN
BLU
WHT
BRN
BLOWER CONTRL COIL
USE COPPER CONDUCTORS ONLY.
IF ALUMINUM CONDUCTORS ARE PRESENT,
ALL APPLICABLE LOCAL AND NATIONAL
CODES MUST BE FOLLOWED.
SEE INSTALLATION INSTRUCTIONS FOR PROPER
LOW VOLTAGE FIELD WIRING CONNECTIONS.
LEGEND
LS - LIMIT SWITCH
SEQ - SEQUENCER
HE - HEATING ELEMENT
FL - FUSIBLE LINK
H - SEQUENCER HEATER
RC - RUN CAPACITOR
RLY - RELAY
H
H
H
H
H
H
1199995-UWD-A-0415
10 KW AND BELOW
RC
13 KW AND ABOVE
XFMR-C
XFMR-R
C
R
G
SPEEDUP
N.O.
N.C.
COM
BLOWER
TIME
DELAY
24V
240V
COM
208V
1
2
3
4
5
6
1
2
3
4
5
6
BLOWER
MOTOR
RC
PRP
BRN
GRN
BLK
H M L
PRP
BLOWER
MOTOR
RC
ALTERNATE
CONNECTION
AP60
RFCX60
MP20
ALT
CONN
L2
L1
L2
L1
HE1
HE2
LS
LS
HE3
LS
H
H
FL
FL
FL
3
1
5
4
SEQ2
SEQ1
RED/WHT
EQUIPMENT
GROUND
YEL
BRN
YEL
BLK
RED
BRN
WHT
BLU
PRP
BLU
RED
BLU
BLU
1
2
3
4
5
6
L2
L1
L2
L1
HE1
HE2
LS
LS
HE3
LS
H
H
FL
FL
FL
3
1
5
4
SEQ1
RED/WHT
EQUIPMENT
GROUND
BLU
BLK
BLK
RED
RED
BRN
WHT
BLU
PRP
BLU
BLU
H
H
3
1
5
4
SEQ2
BLU
L2
L1
BLU
HE5
LS
FL
HE4
LS
FL
BRN
BLK
BLK
YEL
YEL
YEL
RED
RED
RED
HE4
LS
FL
H
H
3
1
5
4
BLU
BLK
BLU
L2
L1
RED/WHT
EQUIPMENT
GROUND
YEL
BLK
WHT
BLU
PRP
YEL
BLU
HE1
LS
FL
WHEN INSTALLING HEATER KIT, BE SURE THE BLOWER SPEED IS
SET TO THE SPEED SPECIFIED FOR THE AIR HANDLER/HEATER KIT
COMBINATION ON THIS UNIT'S INSTALLATION INSTRUCTIONS.
HEATER KITS:
6HK*6500206
6HK*6500506
HEATER KITS:
6HK*6501806
6HK*6502006
HEATER KIT:
6HK*6502506
1
2
3
4
5
6
1
2
3
4
5
6
HEATER KITS:
6HK*6501306
6HK*6501506
L2
L1
L2
L1
HE1
HE2
LS
LS
HE3
LS
FL
FL
FL
SEQ2
SEQ1
RED/WHT
EQUIPMENT
GROUND
BLK
RED
YEL
BLK
RED
BLK
BRN
WHT
BLU
PRP
BLU
YEL
BLU
1
2
3
4
5
6
L2
L1
HE2
LS
FL
RLY 2
RLY 1
RED/WHT
EQUIPMENT
GROUND
YEL
BLK
BLU
YEL
WHT
BLU
PRP
BLU
BLU
HE1
LS
FL
WHT
HEATER KITS:
6HK*6500806
6HK*6501006
1
2
3
4
5
6
RLY
BLU
BLU
BLU
YEL
YEL
RLY
BLU
BLU
BLU
YEL
BLU
YEL
BRN
RLY 2
RLY 1
YEL
BLK
BLK
BLK
RED
RED
BLU
YEL
WHT
BLU
H
H
3
1
5
4
SEQ3
YEL
BRN
BLU
RLY 2
RLY 1
BLU
WHT
RED
BLK
BLK
BLU
BLK
3
1
5
4
H
H
3
1
5
4
H
H
BLK
SEQ or RLY
SEQ or RLY
AIR HANDLER - WITH NO HEAT KIT
WIRING DIAGRAM
208-240 VOLT
HE5
LS
FL
HE4
LS
FL
HE3
LS
FL
HE2
LS
FL
HE1
LS
FL
YEL
OD UNIT CONTACTOR
SEQ or RLY
SEQ or RLY
SEQ or RLY
SEQ or RLY
SEQ or RLY
SEQ or RLY
SEQ or RLY
SEQ or RLY