User Manual

76 / 87
Appendix A: WIMAN Hardware
Hybridcable Type 2 (H2-X21C-25)
This Hybrid cable is being used as an internal termination cable
when installing a WIMAN on a readio-tower on on a rooftop.
The 25pin SubD-plug (male) is connected to the 12x2 Dataca-
ble, which leads from the WIMAN to the Router. All other con-
nectors are the same as on Hybrid cable type 1.
SubD 25
male
S 25
11 x 0,15 mm², shielded
5 x 0,15 mm²
3 x 0,15 mm², shielded
SubD 15
female
with nuts
300 mm
S 15
S 9
SubD 9
female
with nuts
DIN Renk, 3 pin,
180 de
g
rees, male
Hybrid cable Type 3 (H3-X21C-37)
This hybrid cable is attached with outdoor installations between
the WIMAN and the data cable (12x2). The SMA socket serves
for the link to the synchronisation bus, if several WIMAN de-
vices are mounted in direct proximity.
S 37
SubD 37
female
SMA
female
SubD 25
male
with nuts
RG 316
23 x 0,15 mm², shielded, paired
400 mm
S 25
Date: 27. June 2000
2 mm
6 mm