User Manual

42 / 87
3 Configuration of the WIMAN radio modem
4.
Leave the configuration mode by entering the command
exit
(see page 17).
5.
Proceed as shown in chapter 3.4.1 on page 36.
3.5.3 Setting of a Password for Authorization Level two
(Enable)
A password for authorization level two is always required.
However, it can be changed to suit the requirements of the Pro-
vider.
To change the password for authorization level two proceed as
follows:
1.
Access the command line prompt of authorization level
two:
a)
Access authorization level one (See chapter 3.5.1on
page 40)
b)
Enter the command
enable
.
As a password is always required, you need to enter
the correct password
Enter password: ****
Type in the correct password (pay attention to upper-
and lowercase characters) and press ENTER.
c)
The command line prompt appears, e.g.:
WIMAN-II #
Proceed with No. 2.
Direct entrance over the password-protected com-
mand line level of authorization levels one and two:
When accessing the command line prompt of authori-
zation level one the following prompt will appear::
Enter password: ****
Enter the password for the authorization level two (pay
attention to upper- and lowercase characters).
The command line prompt should appear, e.g.:
WIMAN-II #
2.
Change from the command mode of authorization level two
(indicated by the #- sign at the end of the command line
prompt) into the configuration-mode by entering the com-
mand
config
.
The command line prompt may look as follows:
WIMAN-II (config) #
3.
Enter the command
passwd enable
and press
ENTER
.