User Manual

2 The WIMAN Command Line Level
22 / 87
The parameter
ConPageSize
indicates, how many lines in the re-
spective command line window (terminal window over RS-232-
interface) are to be represented, before the continuous output of
the parameters is stopped. The size of an output page is thus fi-
nally determined.
Authorization Level: 2
Preset value: 24
Scope: 10 ... 100
The parameter
ConPauseMode
determines if the output on the
display shall be stopped after the number of lines given with
ConPageSize
or not.
Authorization Level: 2
Preset value: On
Scope: On, Off
The parameter
ConParity
determines the type of the parity
check on the serial RS-232-interface.
Authorization Level: 2
Preset value: none (no parity check)
Scope: none, odd, even
The parameter
ConStopBit
determines, how many stop bits are
supposed to follow the data bits on the serial RS-232-interface.
Authorization Level: 2
Preset value: 1
Scope: 1, 2
2.5.3 Parameter for the serial data Interface
The following parameters serve for the configuration of the se-
rial data interface and are important for correct data exchange
between the Router and the WIMAN radio data modem.
The parameter
SerBaudrate
determines the Baud rate for the
data communication on the X21-interface.
Authorization Level: 1
Preset value: 2048000
SerBaudrate
ConParity
ConStopBit
ConPageSize