User Manual

2 The WIMAN Command Line Level
23 / 90l
Scope: 19200, 48000, 64000, 128000,
256000, 512000, 1024000,
2048000
The parameter SerCRC determines the error correction proce-
dure that can be used (check total of 16 or 32 bits).
Authorization Level: 2
Preset value: 16
Scope: 16, 32
The parameter SerEncode determines the coding procedure on
the X.21-interface. It can be selected between the values NRZ or
NRZI. NRZ is for No Return zero and NRZI for NO Return
zero Inverted.
Authorization Level: 2
Preset value: NRZ
Scope: NRZ, NRZI
Determines whether the external control signal is analyzed
(SerControl normal) on the synchronous serial interface
(e.g. C with X.21) or whether the signal is set internally by the
WIMAN device (SerControl internal). Latter adjust-
ment is particularly necessary with the application of 10paired
(10x2) data cables (between hybrid cables 2 and 3), since the C-
line of the DTE is not been transferred here.
Authorization Level: 2
Preset value: Normal
Scope: Normal, Intern
2.5.4 Network-Parameter
The parameter IPDefaultGW determines, to which IP address IP
packages are to be sent, whose target is not situated in the con-
figured local area network and thus is not known in this network
Authorization Level: 2
Preset value: 0.0.0.0
Scope: valid IP-address
The parameter IPEthAddress determines the IP address, which is
bound to the Ethernet interface (an IP address from the local
area network).
Authorization Level: 2
IPDefaultG
W
IPEthAddress
SerCRC
SerEncode
SerControl