User's Manual
5
6
Contact Wilson Electronics Technical Support Team with any questions at 866-294-1660
or email: tech@wilsonelectronics.com. Mon. -Fri. Hours: 7 am to 6 pm MST.
sure the antenna is not pointing across your own roof or at the Inside
Antenna as this will cause the oscillation protection circuitry to shut down
the Signal Booster.
Warning:
Lightning protection is recommended for all installations
(sold separately, Part #859902-50 Ohm shown below).
Selecting a Direction for the Outside Antenna
Select a location on the roof of the building to install the Outside Antenna.
Use a cell phone in test mode to find the strongest signal from the cell tower.
See page below for more information. To get the strongest signal possible, it
is very important to set up your Outside Antenna properly. The inside and the
Outside Antenna must be mounted in such a way that they are able to pick
up the best possible cell signal on the outside of the building and provide the
best possible signal on the inside of the building. Mount the Outside Antenna
as high as possible facing the cell tower in an area with the best possible
signal coverage. Note:
Never point the front of a directional antenna toward
the Inside Antenna. See Figures 1 & 2 on page 10.
Finding the Strongest Signal
When installing your Signal Booster’s Outside Antenna, aiming it towards
the best signal source from you service provider is important. The best way
of getting the strongest signal is to have one person on the roof to rotate
Lightning
Surge Protector
(sold separately)
Signal Booster
Surge Protector
Power Strip recommended for all AC power supplies
Ground Wire
(not included)
To Outside
Antenna
To Inside
Antenna
Installing Lightning Protection
(sold separately)
Install the Lightning Surge
Protector (LSP) close to the Signal
Booster. Attach the cable from
the Outside Antenna to the surge
protector, using a short length of low
loss cable; attach one end to the
LSP and the other to the Outside
Antenna connector on the Signal
Booster. Ensure the LSP is properly
grounded (ground wire not included).
Visit www.WilsonElectronics.com
or call 800-204-4104 to purchase.