User's Manual
11
Contact Wilson Electronics Technical Support Team with any questions at 866-294-1660
or email: tech@wilsonelectronics.com. Mon.- Fri. Hours: 7 am to 6 pm MST.
12
Figure 1
OVERLOAD
62 AA’ 72
OVERLOAD
62 AA’ 72
Band
Select
Reset
PUSH
PUSH
800
MHz
1700
/2100
MHz
UP
DOWN
PUSH
PUSH
1900
MHz
700
MHz
Band
Select
Reset
PUSH
PUSH
800
MHz
1700
/2100
MHz
UP
DOWN
PUSH
PUSH
1900
MHz
700
MHz
Wilson
®
Electronics, Inc.
Power
AG Pro
Quint
Selectabl e
SMART
TECHNOLOGY
™
™
GAIN
GAIN
2
1
3
4
Button Operation
1 FACTORY RESET – Pushing the “Reset” (refer to Figure 1 on page
11) button will reset the Signal Booster to max gains and restart the
installation timer.
Note: If the Signal Booster is unplugged, a similar situation will occur,
except the manual gains will remain the same as they were
before being unplugged.
2 BAND SELECT – Pressing the “Band Select” button will cycle through
the bands and LTE selection.
a. The selection will flash for 15 minutes.
b. The “UP/DOWN” (refer to Figure 1) buttons are enabled only when a
selection is flashing.
c. If install period is over, pressing “BAND SELECT” will return it to
install mode.
3 UP – Controls the manual gain adjustment.
a. Pressing the “UP” (refer to Figure 1) button will cause the selected
gain to increase in 1dB increments.
b. If the “A” or “B” is flashing, “UP” will toggle between Band 12(A) and
Band 13(B).
c. Gains will never go higher than the maximum (70 dB or 75 dB).
4 DOWN – Controls the manual gain adjustment.
a. Pressing the “DOWN” (refer to Figure 1) button will cause the
selected gain to decrease in 1dB increments.
b. If the “A” or “B” is flashing, “DOWN” will toggle between Band 12(A)
and Band 13(A).
c. Gains will never go lower than the minimum (40 / 45 dB).
d. Holding the “DOWN” button on startup will turn all of the manual
gains to minimum (48/45 dB) to aid the installer during setup.