Blocked Vent Shut-Off (BVSO) for chimney venting 
(OPTIONAL) 
It is imperative that this device be installed by a 
qualified agency. 
This device is designed to detect the insufficient evacuation of 
combustion gases in the event of a vent blockage. In such a case 
the thermal switch will shut down the oil burner. The device will then 
need to be re-armed MANUALLY. 
In the event that the BVSO repetitively shuts down the oil burner, a 
qualified technician needs to evaluate the cause of this shut down. 
Refer to the figures 3 to 5 at section 6, Wiring Diagrams and detailed 
instructions supplied with the BVSO for the installation and wiring 
procedures. 
It is also essential that the BVSO be maintained annually. 
For more details refer to the instructions supplied with the device 
itself, as well as the Maintenance Section. 