Specifications
TMP Oil Furnaces – Furnace Manual
26 670-000-004/1010
12 Dimensions and ratings
Model TMP-105, Burners data
Airflow data (CFM)
Pump Combustion
pressure air adjustment
BTU/h
(PSIG)
(band/shutter)
70,000 0.50 0.50 - 70A 100 F0 Yes 2 3/4 #3383 0 / 4.5
88,200 0.63 0.50 - 70A 155 F0 Yes 2 3/4 #3383 0 / 8
105,000 0.75 0.60 - 70B 155 F0 No 2 3/4 #3383 0 / 7.5
Pump
pressure
BTU/h
(PSIG)
88,200 0.63 0.50 - 60A 155
105,000 0.75 0.60 - 60A 155
Pump
pressure
BTU/h
(PSIG)
70,000 0.50 0.50 - 60A 100
88,200 0.63 0.50 - 60A 155
105,000 0.75 0.60 - 60A 155
TMP-105
Bar # 0.50 / 0.50
Bar # 0.60 - 0.65 / 0.60
Bar # 0.75 / 0.75
CARLIN BURNER - EZ-1 - Tube insertion 5 3/16"
TMP-105
0 / 4
0 / 3
Model
Input
TMP-105
BECKETT BURNER - Model AFG (3450 RPM) - Tube insertion 5 1/8"
Input
Model
Firing rate
USGPH
Nozzle
(Delavan)
Head
Low firing
rate baffle
Static disc
Combustion
air adjustment
RIELLO BURNER - Model 40-F3 - Tube insertion 5 3/16"
Model
Input Firing rate
USGPH
Nozzle
(Delavan)
(Turbulator / Band)
Firing rate
USGPH
Nozzle
(Delavan)
Combustion
air adjustment
(Bar / Band)
0.1 0.2 0.3 0.4 0.5 0.6 0.7
Med-Low 820 810 795 785 770 760 750
Med-High 1115 1080 1045 1010 970 935 900
High 1435 1380 1325 1270 1210 1155 1100
Notes :
Airflow values in cubic ft per minute (CFM) rounded to nearest 5 CFM.
Data taken with filters in place.
External static pressure
Model Blower speed
TMP-105