Instructions / Assembly
Rev. 4/18/05 Page 2 of 7 
  SETTING 
0
 F / 
0
C SCALE 
The factory setting for temperature is 
0
 F.  To change this setting to 
0 
C, first 
•  Press the ON 
key and the OFF key on the transmitter at the same time this 
will change from 
0 
F to 
0 
C. Follow this same procedure to change from 
0 
C back to 
0
 F. 
MANUAL FUNCTION 
To operate the system in the manual “MODE” does the following. 
ON OPERATION 
Press the ON
 key the appliance flame will come on. During this time the LCD 
screen will show ON, after 3 seconds the LCD screen will default to display 
room temperature and the word TEMP will show. (Flame icon will appear on 
LCD screen in on mode) 
OFF OPERATION 
Press the OFF
 key the appliance flame will shut off. During this time the LCD 
screen will show OF, after 3 seconds the LCD screen will default to display 
room temperature and the word “TEMP” will also show on the screen. 
THERMOSTAT FUNCTION 
SETTING DESIRED ROOM TEMPERATURE
This remote control system can be thermostatically controlled when the 
transmitter is in the THERMO mode (The word ROOM
 must be displayed on 
the screen). To set the THERMO MODE and DESIRED room temperature, 
Press the MODE
 key until the LCD screen shows the word ROOM, then the 
remote is in the thermostatic mode. 
Press and hold the SET
 key until the desired set temperature is reached. (By 
pressing and holding the set key the LCD screen set numbers will increase 
from 45
0
 to 99
0 
then restart over at 45
0 
) Next release the SET key. The LCD 
screen will display the set temperature for 3 seconds and the LCD screen will 
flash the set temperature for 3 seconds, then the LCD screen will default to 
display the room temperature. 
TO CHANGE THE SET TEMPERATURE
Press and hold the SET
 key until the desired set temperature is reached. (By 
pressing and holding the set key the LCD screen set numbers will increase 
from 45
0
 to 99
0 
then restart over at 45
0 
) Next release the SET key. The LCD 
screen will display the set temperature for 3 seconds, then will flash the set 
temperature for 3 seconds, then the LCD screen will default to display the room 
temperature. 
Press the MODE
 key to disengage the thermo mode. The word ROOM on the 
LCD screen will not show when the thermo is not in operation. 
NOTE: The highest SET temperature is 99
0
 Fahrenheit (32
0 
 Celsius) and the 
lowest temperature is (45
0
 Fahrenheit (6
0 
 Celsius) 
TEMP
TEMPSET
THERMO SET 
SCREEN WHILE 
DEPRESSING OFF 
KEY
TEMP
SCREEN AFTER 3 
SECOND DEFAULT 
ROOM
TEMP
THERMO
MODE
TEMP
SCREEN AFTER 3 
SECOND DEFAULT 
ROOM
TEMP
THERMO
ON
ROOM
TEMP
THERMO
OFF
SCREEN WHILE 
DEPRESSING ON 
KEY