Specification Sheet
DIRECTVENT FURNACES
1403822 1403821 14,000 9,800 70 65 18 7 ⅛ 26 ¼
MILLIVOLT 56
2203822 2203821 22,000 16,462 75 67 32 ⅛ 10 ¼ 28
MILLIVOLT
98
3003822 3003821 30,000 21,000 70 66 32 ⅛ 10 ¼ 28
MILLIVOLT
100
BTU/hr.
INPUT
BTU/hr.
OUTPUT
THERMOSTAT
SHIPPING
WEIGHT
(LBS.)
PROPANENATURAL
MODEL NUMBER
AFUETHERMAL
EFFICIENCY PERCENT
DEPTHWIDTH
DIMENSIONS (INCHES)
HEIGHT
“MATCHLESS” PILOT IGNITER
All models include a “matchless” pilot igniter that assures
convenient pilot lighting without matches.
NO ELECTRICITY REQUIRED
Great during outages.
CONTEMPORARY FINISH
Soft-white, powder-coat, heat-resistant finish to compliment
any decor.
INTERIOR FURNACE CLEARANCES
3/16 from finished floor - 14,000 BTU/hr. models.
2 from an intersecting wall.
5 ½ from finished floor - 22,000 and 30,000
BTU/hr. models. 24 from top of
appliance to ceiling or other obstructions
12 clearance for curtains
24 Maximum wall thickness.
30 14,000 BTU/hr. models. from top of appliance to
ceiling or other obstructions - 22,000 and 30,000
BTU/hr. models.
• Read owner’s manual before using/installing.
• Photographs are representative only.
• Check local codes and ordinances for permitted uses.
• Consult installation manual for clearances prior to installation.
• We reserve the right to amend product specifications without notice.
• Installation and servicing recommended by a qualified service person.
• Please read the warranty for any limitations of disclaimers. Combustion chamber carries a 10-year
limited warranty. All other parts carry a one-year limited warranty.
• Venting must comply with the “Venting and Chimney Requirements” section of the instruction manual.
• Massachusetts Approval Gl-0816-23, 30K Approval G1-1215-244.
Elevation rating from sea level to 2,000' Consult Owner’s Manual for installation of product at elevations over 2000' 1/2 Gas Connection
ACCESSORIES
THERMOSTAT SOLD SEPARATELY
part number P322016
HIGH CAPACITY BLOWER
Blower is easily added to the furnace. Comes with a fully
automatic fan switch.11 5V power supply required.
Model 2302 for 22,000 and 30,000 BTU/hr.
Model 2303 for 14,000 BTU/hr.
Shipping weight 6 lbs.
VENT-CAP GUARD
Protects pedestrian traffic from vent-cap heat.
Model 9308 - Shipping weight 3 lbs.
VENT SHIELD DEFLECTOR
Insulated, galvanized sheet for all direct-vent units.
Model 4318 - Shipping weight 9 lbs. (Oversized)
VENT EXTENSIONS
To meet your installation needs, all models accommodate optional
through-the-wall vent which may extend up to 24 maximum.
FACE PANELS
THIN-WALL COLLAR KIT
Model 9307 - For wall thicknesses from 1 to 5. Installs with vent kit.
Shipping weight 4 lbs.
CONVERSION KITS
250 W. Laurel Street Colton, CA 92324 USA Subject to change without notice © 2019 Williams L1109, 12-19
WARNING: This product can expose you to chemicals can which is known including
to the State epichlorohydrin of defects California to and/or cause other cancer
reproductive and birth harm. For more information go to www.p65warnings.ca.gov
IMPORTANT
FEATURES
MODEL
9301
9303
9304
LENGTH
15
24
15
APPLICATION
22038 & 30038 SERIES
14038 & 30038 SERIES
14038 SERIES
SHIP WT.
7 LBS.
10 LBS.
7 LBS.
MODEL
4309
4313
APPLICATION
14038 SERIES
22038 & 30038 SERIES
SHIP WT.
16 LBS.
29 LBS.
14038 8939 8942
22038 8940 8943
30038 8941 8944
MODEL
SERIES
NATURAL
TO
PROPANE
PROPANE
TO
NATURAL
DIRECT-VENT SAFETY
For clean, comfortable heat
when and where you want it.
The gas flame is completely
sealed inside, away from all
contact with room air. Air
necessary for combustion is
drawn into the chamber from
outside through the vent,
and combustion products
are vented directly to the
outside. Only clean, gentle
heat, in continuous circulation
is de livered into the room.
Windows and doors stay
closed because no room air
is used for combustion.
WARM AIR
TO HEAT
ROOM
FRESH AIR
FROM
OUTSIDE
EXTERIOR WALL
COMBUSTION
AIR OUTLET
OUTSIDE
COOL ROOM