Brochure

VENTED ROOM HEATERS
“MATCHLESS” PILOT IGNITER
All models include a “matchless” pilot igniter that assures convenient pilot
lighting without matches.
CONTEMPORARY FINISH
Black, powder-coat, heat-resistant finish to compliment any decor.
INTERIOR FURNACE CLEARANCES
Elevation rating from sea level to 2,000' Consult Owner’s Manual for installation of product at elevations over 2000' 1/2ʺ Gas Connection
ACCESSORIES
THERMOSTAT SOLD SEPARATELY part number P322016
BLOWER
MODEL 2102 quiet, heavy-duty blower is available for larger rooms where faster heat
circulation is desired. 150 CFM, 120V. Shipping weight 9 lbs.
FLOORBOARDS
Contemporary black color to match the heater with scratch-resistant powder-coat finish.
Model 4163 for 50,000 and 65,000 BTU/hr. models. (Oversized) shipping weight 16 lbs.
Model 4167 for 20,000 and 35,000 BTU/hr. models. (Oversized) shipping weight 10 lbs.
CONVERSION KITS
250 W. Laurel Street · Colton, CA 92324 USA Subject to change without notice © 2021 Williams L1013, 4/21
WARNING: This product can expose you to chemicals including epichlorohydrin which is known to the State of California
to cause cancer and birth defects and/or other reproductive harm. For more information go to www.p65warnings.ca.gov
FEATURES
MODEL
SERIES
A B C D E
200 SERIES
2 36 3 24 17
350 SERIES
6 57 6 24 21 ¼
500 SERIES
6 57 6 24 23
650 SERIES
6 57 6 24 25 ½
MODEL
SERIES
NATURAL TO
PROPANE
PROPANE TO
NATURAL
200 SERIES
8945 8949
350 SERIES
8946 8950
500 SERIES
8947 8951
650 SERIES
8948 8952
C
B
A
D
E
MODEL NO.
BLOWER
OPTION
BTU/hr.
INPUT
BTU/hr.
OUTPUT
DIMENSIONS (INCHES)
THERMOSTAT
TYPE SOLD
SEPARATELY
VENT SIZE
INCHES
SHIPPING
WEIGHT
LBS.
NATURAL PROPANE
WIDTH
DEPTH HEIGHT
ENCLOSED FRONT
2001622A 2001621A
NO BLOWER
20,000 15,500 23 12 3/8 21 9/16 MILLIVOT 3 45
3501522A 3501521A
NO BLOWER
35,000 25,000 25 16 28 ⅞ MILLIVOT 4 74
3501922A 3501921A
INCLUDED
35,000 25,000 30 16 28 ⅞ MILLIVOT 4 83
5001522A 5001521A
NO BLOWER
50,000 34,500 30 17 33 ¼ MILLIVOT 4 103
5001922A 5001921A
INCLUDED
50,000 34,500 30 17 33 ¼ MILLIVOT 4 112
6501522A 6501521A
NO BLOWER
65,000 47,000 34 20 ½ 33
7
/8 MILLIVOT 5 128
6501922A 6501921A
INCLUDED
65,000 47,000 34 20 ½ 33
7
/8 MILLIVOT 5 137
FEATURES
MODEL NO.
BLOWER
OPTION
BTU/hr.
INPUT
BTUHR.
OUTPUT
DIMENSIONS (INCHES) THERMOSTAT
TYPE SOLD
SEPARATELY
VENT
SIZE
INCHES
SHIPPING
WEIGHT
LBS.
NATURAL PROPANE WIDTH DEPTH HEIGHT
OPERATES W/O
ELECTRICITY
RESETTABLE
VENT SWITCH
CONVERTIBLE
GAS VALVES
3502522A 3502521A NO BLOWER 35,000 25,000
25
16 28 ⅞
CABINET OR WALL
4 81
3502922A 3502921A INCLUDED 35,000 25,000 25 16 28 ⅞
CABINET OR WALL
4 90
5002522A 5002521A NO BLOWER 50,000 34,500 30 17 33 ¼
CABINET OR WALL
4 108
5002922A 5002921A INCLUDED 50,000 34,500 30 17 33 ¼
CABINET OR WALL
4 117
6502522A 6502521A NO BLOWER 65,000 47,000 34 20 ½ 33
7
/8
CABINET OR WALL
5 135
6502922A 6502921A INCLUDED 65,000 47,000 34 20 ½ 33
7
/8
CABINET OR WALL
5 144
FIREPLACE FRONT
ANY WARRANTY CONSIDERATIONS ARE CONTINGENT ON INSTALLATION BY
A QUALIFIED INSTALLER (CONTRACTOR). SELF-INSTALLATION IS PROHIBITED
AND WILL INVALIDATE YOUR WARRANTY.
Read owner’s manual before using/installing.
Photographs are representative only.
Check local codes and ordinances for permitted uses.
Consult installation manual for clearances prior to installation.
We reserve the right to amend product specifications without notice.
Installation and servicing recommended by a qualified service person.
Please read the warranty for any limitations of disclaimers. Combustion chamber carries a 10-year
limited warranty. All other parts carry a one-year limited warranty.
Venting must comply with the “Venting and Chimney Requirements” section of the instruction manual.
Massachusetts Approval Gl-0816-23.
IMPORTANT