Installation guide
7
CO
NFIGURATION
SE
TTINGS
Figure 8
Adjust switch settings on rear of
MOD 232 Modulator here:
Figure 8 illustrates how to configure your system using the DIP switches (Figure 7) on the back of the
MOD 232 Modulator. This diagram is also printed on top of the MOD 232 Modulator unit for quick
reference.
Figure 7: Configuration Switches
COMPRESSOR GAIN
The MOD 232’s Compressor Gain is set in “Moderate” mode from the factory. Use this setting for simultaneous
interpretation. Be sure that the compress control, located on the front of the MOD 232 (Figure 6, page 6), is turned fully
counter-clockwise. Compression can be added if desired by turning the compress control clockwise.
For hearing assistance applications, the MOD 232’s Compressor Gain can be set to “Maximum” mode. For additional
compression, use a tuning wand (PLT 005) or small screw driver and gently turn the compress control (Figure 6, page 6)
on the front of the MOD 232 clockwise.
IMPORTANT: Channel A and Channel B must be set to different frequencies!