User manual

DigiWave 300 Series Digital Transceiver and Receiver
19
1-WAY SETUP FOR SIMULTANEOUS INTERPRETATION
1-way
Speak Only
(Main Speaker)
1-way
Receive / Speak
(Interpreter)
2-way
Receive Only
1-way
Repeater
1-way
Receive Only
2-way
Intercom
2-way
(Tour Guide)
1-way Modes
2-way Modes
1 32 4
5 6 87
9 10 11 12
13 14 15
Press and hold POWER
button for 2 seconds to
turn DLT ON.
Press and Hold and
for 3 seconds to enter
programming mode.
The other icons will disappear
and the current mode icon
will be blinking on the screen.
Use the buttons
to change to 1-way
Simultaneous Interpretation
mode.
Press the button to
select this mode and move
to the next setting.
The GROUP icon will be
blinking. Use the
buttons, then the button
to choose group.
Use to select
Master (first unit only). There
must be only one Master
per group. Press . .
Push to advance to the
next digit.
The TIME icon and hour will
be blinking. Use the
buttons then the button
to choose hour (am/pm).
The minutes will be blinking.
Use to adjust, then
to choose the minute.
Repeat steps 11 and 12 until
all four digits are adjusted.
Press to advance to
the next setting.
The first secure code digit will
be blinking. Use to
adjust the first digit. Press
to advance to the next digit.
The currently selected mode
will be blinking. This is the
beginning of programming.
Press and Hold and
for 3 seconds to exit
programming mode.
The CH icon will be
blinking. Use the
buttons, then the button
to choose channel 0 (first unit).