 ADA Handrails Installation Instructions  2  ©2018 Railing Accents™. All Rights Reserved. Version 2.2
5.  When connecting more than one light, run a 16/2 GA Wire 
from post to post. Feed the ends of the wire through the 
pre-drilled 1/4" hole. Lay wire inside upper rail channel so 
not to interfere with top rail snap installation.
6.  Connect the wire to the rst post cap light and if 
installing more than one light, connect another wire to 
UR connector to continue lead wire (three wires in UR 
Connector). See g. 3 and g. 4.
NOTE: To ensure a water tight seal, push all 
connectors rmly together.
7.  Continue wiring all post caps.
8.  Mount transformer where it is exposed to daylight and 
within reach of an outdoor CGFI outlet. DO NOT PLUG 
IN UNIT.
9.  Connect 16/2 GA wire (lead wire) to power supply.
10. Plug in transformer and turn to “ON” position.
11. If all lights are working and wires are properly secured, 
install top rail snaps.
FIG. 3
UR CONNECTORS
STEP 1 – Strip wire ends.
STEP 1 – Insert up to three wires fully 
into connector.
STEP 2 – Using pliers, crimp blue top 
until ush.
This low voltage system allows for connecting wires to light 
or extension cable in either order. There are no positive or 
negative wires.
FIG. 4
LED LIGHT
P/N: LE045310 OR 
LE045311
16/2 GA WIRE
UR CONNECTORS
16/2 GA 
WIRE
3” LED POST CAP INDIRECT LIGHT – ASSEMBLY P/ N: LE045311
LIGHT HOUSING
POST
TREE CLIPS
INDIRECT LIGHT
INDIRECT LIGHT
WIRE
LIGHT HOUSING
CAP
PHILLIPS SCREWS
1. INSTALL 
 INTO
 LIGHT HOUSING 
THEN INSTALL 
INDIRECT 
 LIGHT
 (L.E.D'S DOWN) AS SHOWN ENSURING 
INDIRECT LIGHT WIRE
 FEEDS DOWN THROUGH 
POST
.
2. ATTACH 
LIGHT HOUSING
 ONTO 
POST
 AND SECURE USING
AS SHOWN.
#2 PHILLIPS DRIVER
3. PLACE 
CAP
 ONTO 
LIGHT HOUSING
 AND SECURE USING
INSTALLATION INSTRUCTIONS
INDIRECT LIGHT
LE045311M
4X 6-32 X 3/8” LONG
GASKET
4X CHRISTMAS
4X CHRISTMAS TREE CLIPS
4X 6-32 X 3/8” LONG 
PHILLIPS SCREWS.
LIGHT HOUSING
POST
TREE CLIPS
INDIRECT LIGHT
INDIRECT LIGHT
WIRE
LIGHT HOUSING
CAP
PHILLIPS SCREWS
1. INSTALL 
 INTO
 LIGHT HOUSING 
THEN INSTALL 
INDIRECT 
 LIGHT
 (L.E.D'S DOWN) AS SHOWN ENSURING 
INDIRECT LIGHT WIRE
 FEEDS DOWN THROUGH 
POST
.
2. ATTACH 
LIGHT HOUSING
 ONTO 
POST
 AND SECURE USING
AS SHOWN.
#2 PHILLIPS DRIVER
3. PLACE 
CAP
 ONTO 
LIGHT HOUSING
 AND SECURE USING
INSTALLATION INSTRUCTIONS
INDIRECT LIGHT
LE045311M
4X 6-32 X 3/8” LONG
GASKET
4X CHRISTMAS
4X CHRISTMAS TREE CLIPS
4X 6-32 X 3/8” LONG 
PHILLIPS SCREWS.
FIG. 1 FIG. 2
1.  INSTALL GASKET INTO LIGHT HOUSING, THEN 
INSTALL INDIRECT LIGHT (L.E.D.S DOWN). ENSURE 
INDIRECT LIGHT WIRE FEEDS DOWN THROUGH POST. 
SEE FIG. 1.
2.  ATTACH LIGHT HOUSING ONTO POST AND SECURE 
USING 4X CHRISTMAS TREE CLIPS. TWO CLIP SIZES 
MAY BE PROVIDED – USE THE SIZE TO BEST FIT 
HOLES IN POST. SEE FIG. 1.
3.  CONNECT LIGHT WIRE 
TO LEAD WIRE WITH UR 
CONNECTORS.
4.  PLACE CAP ONTO 
LIGHT 
HOUSING
 AND SECURE 
USING 4X 6-32 X 3/8" LONG 
PHILLIPS SCREWS. 
SEE 
FIG. 2.
TOOLS NEEDED: Phillips Head Screwdriver
1.  INSTALL GASKET INTO LIGHT HOUSING. SEE FIG. 1.
2.  ATTACH LIGHT HOUSING ONTO POST AND SECURE 
USING 4X CHRISTMAS TREE CLIPS. TWO CLIP SIZES 
MAY BE PROVIDED – USE THE SIZE TO BEST FIT 
HOLES IN POST. SEE FIG. 1.
3.  PLACE PERIMETER LIGHT ONTO LIGHT HOUSING 
ENSURING PERIMETER LIGHT WIRE FEEDS DOWN 
THROUGH POST. 
SEE FIG. 2.
4.  CONNECT LIGHT WIRE 
TO LEAD WIRE WITH UR 
CONNECTORS.
5.  PLACE CAP ONTO 
PERIMETER LIGHT AND 
SECURE USING 
4X 6-32 X 7/8" LONG PHILLIPS 
SCREWS. SEE FIG. 2.
3” LED POST CAP PERIMETER LIGHT – ASSEMBLY P/N: LE045310
TOOLS NEEDED: Phillips Head Screwdriver
LIGHT HOUSING
POST
TREE CLIPS
4X CHRISTMAS
GASKET
GASKET
LIGHT HOUSING
PERIMETER LIGHT
CAP
PHILLIPS SCREWS
PERIMETER LIGHT WIRE
POST
1. INSTALL 
 INTO
 LIGHT HOUSING 
AS SHOWN.
2. ATTACH 
LIGHT HOUSING
 ONTO 
POST
 AND SECURE USING 
 AS SHOWN.
#2 PHILLIPS DRIVER
3. PLACE 
PERIMETER LIGHT
 ONTO 
LIGHT HOUSING 
ENSURING 
PERIMETER LIGHT WIRE
 FEEDS DOWN THROUGH 
POST
.
4. PLACE 
CAP
 ONTO 
PERIMETER LIGHT
 AND SECURE USING
INSTALLATION INSTRUCTIONS
PERIMETER LIGHT
LE045310M
4X 6-32 X 7/8” LONG
4X CHRISTMAS TREE CLIPS
4X 6-32 X 7/8” LONG 
PHILLIPS SCREWS.
LIGHT HOUSING
POST
TREE CLIPS
4X CHRISTMAS
GASKET
GASKET
LIGHT HOUSING
PERIMETER LIGHT
CAP
PHILLIPS SCREWS
PERIMETER LIGHT WIRE
POST
1. INSTALL 
 INTO
 LIGHT HOUSING 
AS SHOWN.
2. ATTACH 
LIGHT HOUSING
 ONTO 
POST
 AND SECURE USING 
 AS SHOWN.
#2 PHILLIPS DRIVER
3. PLACE 
PERIMETER LIGHT
 ONTO 
LIGHT HOUSING 
ENSURING 
PERIMETER LIGHT WIRE
 FEEDS DOWN THROUGH 
POST
.
4. PLACE 
CAP
 ONTO 
PERIMETER LIGHT
 AND SECURE USING
INSTALLATION INSTRUCTIONS
PERIMETER LIGHT
LE045310M
4X 6-32 X 7/8” LONG
4X CHRISTMAS TREE CLIPS
4X 6-32 X 7/8” LONG 
PHILLIPS SCREWS.
FIG. 1 FIG. 2
FOR USE WITH LANDSCAPE LIGHTING SYSTEM ONLY. THIS DEVICE IS ACCEPTED AS A LANDSCAPE LIGHTING SYSTEM WHERE THE SUITABLITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR LOCAL 
INSPECTION AUTHORITIES HAVING JURISDICTION. LANDSCAPE LIGHTING SYSTEMS ARE FOR OUTDOOR USE ONLY. POWER SUPPLIES ARE FOR OUTDOOR USE ONLY. NOT FOR USE IN DWELLING UNITS. DO NOT 
MOUNT POWER SUPPLY OR LUMINAIRES WITHIN 10 FT OF A SWIMMING POOL OR SPA. THE SUPPLY CIRCUIT FOR THE LANDSCAPE LIGHTING SYSTEM SHALL BE PROTECTED BY A CLASS A TYPE GROUND FAULT 
CIRCUIT INTERRUPTER. NOT FOR USE WITH SUBMERSIBLE FIXTURES. USE ONLY WITH EASY PLUG CONNECTOR CABLES AND POWER SUPPLIES. FOR ADDITIONAL CABLES PLEASE CALL THE NUMBER BELOW. 
ONLY USE THE EXTENSION CORD SUPPLIED WITH THE PROVIDED POWER SUPPLY. DO NOT USE AN EXTENSION CORD. 5MM ILUMA PULLS 1.6 WATTS PER FOOT. USE ONLY 90% OF THE POWER SUPPLIES WATTAGE, 
ALLOWING 10% FREE. LOW VOLATGE CABLE SHALL: BE PROTECTED BY ROUTING IN CLOSE PROXIMITY TO THE LUMINAIRE OR FITTING, OR NEXT TO A BUILDING STRUCTURE SUCH AS A HOUSE OR DECK; NOT BE 
BURIED EXCEPT FOR A MAXIMUM 6’’ (15.2CM) IN ORDER TO CONNECT TO THE MAIN LOW VOLTAGE CABLE; AND HAVE THE LENGTH CUT OFF SO THAT IT IS CONNECTED TO A CONNECTOR WITH 6’’ (15.2CM) FROM A 
BUILDING STRUCTURE, A LUMINAIRE, OR FITTING.