SDS

YN200U INTERPON D2000 BLACK
Use a properly fitted, particulate filter respirator complying with an approved standard if
a risk assessment indicates this is necessary. Respirator selection must be based on
known or anticipated exposure levels, the hazards of the product and the safe working
limits of the selected respirator.
Safety eyewear complying with an approved standard should be used when a risk
assessment indicates this is necessary to avoid exposure to liquid splashes, mists or
dusts. If contact is possible, the following protection should be worn, unless the
assessment indicates a higher degree of protection: chemical splash goggles. If
operating conditions cause high dust concentrations to be produced, use dust goggles.
Personal protective equipment for the body should be selected based on the task being
performed and the risks involved and should be approved by a specialist before
handling this product.
Eyes
Skin
Respiratory
:
:
:
Chemical-resistant, impervious gloves complying with an approved standard should be
worn at all times when handling chemical products if a risk assessment indicates this is
necessary. Considering the parameters specified by the glove manufacturer, check
during use that the gloves are still retaining their protective properties. It should be
noted that the time to breakthrough for any glove material may be different for different
glove manufacturers. In the case of mixtures, consisting of several substances, the
protection time of the gloves cannot be accurately estimated.
Hands
:
Environmental exposure
controls
:
Emissions from ventilation or work process equipment should be checked to ensure
they comply with the requirements of environmental protection legislation. In some
cases, fume scrubbers, filters or engineering modifications to the process equipment
will be necessary to reduce emissions to acceptable levels.
Solid. [Powder.]
1.2 to 1.9 [ISO 8130-2/-3]
Insoluble in the following materials: cold water and hot water.
Odorless.
9. Physical and chemical properties
Physical state
Relative density
Solubility
Odor
:
:
:
:
Flash point
:
Closed cup: Not applicable.
450 to 600°C (842 to 1112°F)
:
Auto-ignition temperature
Flammable limits
:
Minimum ignition energy
(mJ)
:
20 - 70 g/m
3
5 to 20
The product is stable.
Reactive or incompatible with the following materials:
oxidizing materials
Under normal conditions of storage and use, hazardous decomposition products should
not be produced.
Avoid the creation of dust when handling and avoid all possible sources of ignition
(spark or flame). Take precautionary measures against electrostatic discharges. To
avoid fire or explosion, dissipate static electricity during transfer by grounding and
bonding containers and equipment before transferring material. Prevent dust
accumulation.
10. Stability and reactivity
Chemical stability
Conditions to avoid
Incompatible materials
Hazardous decomposition
products
:
:
:
:
Possibility of hazardous
reactions
:
Under normal conditions of storage and use, hazardous reactions will not occur.
5/10
12/20/2013.