Installation Instructions

Temporary clamp panel
against posts and mark for
miter cuts
*Tip -Lay 2” x 4” board
on nose of stair treads
Level post
FIGURE 1
34” to 38”
from stair nosing
to top of rail
FIGURE 7
FIGURE 5
4x
cut panel
t
o suit
4x cut panel
to suit
Temporary 2” x 4”
spacer board
With #2 pencil place
mark on post at top of
lower stair extrusion
Stair railing
panel
FIGURE 2
FIGURE 3
FIGURE 4
Install, TEK screws,
2x #8 x 3/4” outside
2x #8 x 3/4” inside
Rail clip
FIGURE 6
RAIL CLIP
2X INSTALL
#8 X 3/4"
TEK SCREW
INSIDE
2X INSTALL
#8 X 3/4"
TEK SCREW
OUTSIDE
PENCIL
MARK LINE
CLIP
TOP EDGE
Temporarily
Installed Post
,
Cut 1/16” less than opening size.
Temporarily clamp top and bottom rail snap against
posts and mark for miter cuts. Cut 1/16 less than
opening size.
www.williamsrailing.com