Brochure

Input Wire Diameter Range 5.0 - 6.8 [0.20 -0.27in] 10-12 AWG USE-2/PV V
Maximum number of Input Conductor Slots 9
Maximum number of PV strings 4
Maximum number of Combined Strings 4
Equipment Ground Conductor Type Bare solid or jacketed only
Equipment Ground Conductor Diameter Range 4.0-6.8mm [0.16-0.27 in]
Acceptable Conduit Sizes 19.05mm, 25.4mm [0.75in, 1.0in]
Internal Volume 1840cm [112 in]
Internal Height 72.0mm[2.83 in]
Drill Out Side, Bottom
Congurations
ACE Part
Number
ACE
Conguration
Terminal
Block
Terminal
Block
Internal
Bus
Fuse Holder
Fuse
Combiner
Bus
Grounding
Terminal
DIN Rail
ACE-PT
Pass-Through using Butt
Splices/Wire Nuts
N/A N/A N/A N/A N/A N/A
ACE-1P 1-String Pass-through 2 N/A N/A N/A 1 1
ACE-2P 2-String Pass-through 4 N/A N/A N/A 1 1
ACE-3P 3-String Pass-through 6 N/A N/A N/A 2 1
ACE-4P 4-String Pass-through 8 N/A N/A N/A 2 1
ACE-2C 2-Strings Combiner 2 N/A
Not required for 2-
string combiner
N/A 1 1
ACE-3C 3-Strings Combiner 2 1X 2-Pole 3 1X 3-Pole 2 1
ACE-4C 4-Strings Combiner 2 1X 2-Pole 4 1X 4-Pole 2 1
Mounting Bracket is included with the purchase of the ACE. It is made of lightweight, corrosion resistant, anodized
aluminum. The mounting bracket assembly includes:
1X ACE Mounting Bracket
4X Mounting Screws
2x Bonding Washers