User's Manual

Chapter 6: Appendices
Appendix 1: Demand Mode Output
(12/00) 6-3
Data M
S
D
- - - - - L
S
D
S
P
Units S
P
N C
R
L
F
Note 9 4 5 4 10 6 8
Demand Format Notes
2 Gross weight legend. Selectable in the programming mode as a space, B for
bruto or G for gross.
3 The gross weight data fields are padded with leading spaces to 7 digits.
4 ASCII Space <SP> character, hex value 20.
5 Weight units (lb, kg, g) as selected in setup and by the FUNCTION key.
6 ASCII Carriage Return <CR> character, hex value OD.
7 Optional checksum character: Checksum is defined as the 2s complement of the
seven low order bits of the binary sum of all characters preceding the checksum
character, including the <STX> and <CR> characters. The checksum calculation
for multiple lines of data includes the <LF> character from the previous line of
data.
8 ASCII Line Feed <LF> character, hex value OA.
9 The net weight field is right justified and padded with spaces to seven digits.
A negative net weight is indicated by a minus character before the most
significant digit of the weight value. For example, a weight of 55.00 is printed
with one leading space (sp=space): sp-55.00.
10 Weight field descriptors. The TR and N legends are printed (for net weight)
after the tare and net weight fields to identify them.
Table 6-6: Multiple Line Net Weight