[Incr. ] INCREMENT SIZE
Incr displays momentarily then the current increment size is displayed
for editing. Press the FUNCTION key to toggle through valid selections.
[E SCAL] Empty scale platform and press PRINT to continue.
[15 CAL] Display countdown for zero setting. If motion sensitivity is not disabled
and motion is detected at this step, the display will show [ E 30].
Press PRINT and the display returns to the [E SCAL] prompt.
[Add Ld] Place test weight on the scale platform. Press PRINT.
[0000‘0’] Enter test weight value. No decimal point is permitted. Maximum test
weight is 100% of full scale capacity. There is no minimum test weight
required but METTLER TOLEDO recommends using at least 50% of the
scale capacity.
[15 CAL] Display countdown for calibration. If motion is detected at this step then
the display will show [ E 30]. Press PRINT to return to the [Add Ld]
prompt.
[CAL d] "Calibration done" is displayed momentarily.
[F1.3 0 ] EXPANDED DISPLAY
0 = Normal display mode
1 = Weight displayed in minors
[F1.4 0] PROGRAMMING MODE ACCESS
If CAL jumper is installed on the Controller PCB, this step has no effect,
and the programming mode is always accessible.
If CAL jumper is not installed on the Controller PCB:
0 = No access to view or change values in the programming mode.
1 = Programming blocks F2 and F3 may be accessed to change the
parameters. Programming block F1 may only be viewed.