User's Manual
Chapter 3: Programming and Calibration
F1 Scale Block
(12/00) 3-5
F1 Scale Block
The scale program block allows the user to set and calibrate the features that affect
weighing performance.
[F1.1 2 ] CALIBRATION UNITS
Enter the value that corresponds to the type of test weights that will be
used for calibration.
1 = lb
2 = kg
3 = g
[ GEO 12 ] GRAVITY ADJUST
The WILDCAT scale is calibrated with a GEO code of 12 at the factory. To
adjust the factory calibration to your specific area, refer to Appendix 4 for
your GEO code. Enter the new GEO code and the calibration will
automatically be adjusted for your specific location.
[F1.2 0] SCALE CALIBRATION
0 = Skip Calibration and proceed to F1.3
1 = Enter into the Calibration Sub-block.
[CAP. ] SCALE CAPACITY
“CAP” displays momentarily then current scale capacity is shown. This
value is available for numeric entry editing. Press FUNCTION to clear the
data before entering new data.
Table 3-2 shows all possible selections for capacity and increment.
Increment
Size
SCALE CAPACITIES (lb, kg or g)
0.001 1 - - 2 - 3 4 5 6 - 8 10
0.002 2 - 3 4 5 6 8 10 12 15 16 20
0.005 5 6 - 10 - 15 20 25 30 - 40 50
0.01 10 12 15 20 25 30 40 50 60 - 80 100
0.02 20 24 30 40 50 60 80 100 120 150 160 200
0.05 50 60 - 100 - 150 200 250 300 - 400 500
0.1 100 120 150 200 250 300 400 500 600 - 800 1000
0.2 200 240 300 400 500 600 800 1000 1200 1500 1600 2000
0.5 500 600 - 1000 - 1500 2000 2500 3000 - 4000 5000
1 1000 1200 1500 2000 2500 3000 4000 5000 6000 - 8000 10000
2 2000 2400 3000 4000 5000 6000 8000 10000 12000 15000 16000 20000
5 5000 6000 - 10000 - 15000 20000 25000 30000 - 40000 50000
Table 3-2