Owner's manual
SET-UP
TO RE-CALIBRATE THE THERMOSTAT
The Unitrol thermostat is built to the most
exactingstandardsandisaprecisioninstru-
ment which should never need re-calibration.
However through tampering, misuse or other
reasons, if the thermostat is found to be more
than 10º from normal, a re-calibration may be
performedbyaqualiedservicetechnician.
The following are the steps for this procedure:
1. Turn the thermostat to OFF to allow the unit to cool down.
2. When the water temperature is room temperature, turn the thermostat dial until the main burner
ignites.
3. Slowly,turnthethermostatdialcounterclockwiseuntiltheameontheburnergoesout.
4. Place a thermometer into the water jacket to determine the temperature of the water.
5. Pull off the thermostat dial and lift off the outside cover.
6. Turn the temperature stop to correspond to the actual water temperature. Mark the location of the stop
for reference.
7. Turn the stop slowly until the control snaps off. Holding the stop to prevent rotation, carefully loosen
thestopadjustmentnut(seegure2).
8. Taking care not to move the temperature adjusting screw, turn the stop until it lines up with the tick
mark previously made.
9. Hold the stop in place and tighten the stop adjustment nut.
10. Recheck the OFF temperature.
11. Replace the outside cover and thermostat dial.
THERMOCOUPLECONNECTION
Poor contact between the thermocouple lead and the magnet assembly may cause the valve to be inop-
erative even when the pilot is in proper adjustment and position. If this is the problem, clean and tighten the
contact points. Remove the thermocouple and carefully clean the parts that make contact with the magnet
assembly.
PROCEDUREFORLIGHTINGORRELIGHTINGPILOT
1. Turn GAS COCK handle to “OFF” position, and DIAL ASSEMBLY to lowest temperature position.
2. Waitsufcientlengthoftimetoallowgaswhichmayhaveaccumulatedinburnercompartmentto
escape.
3. Turn GAS COCK handle to “Pilot” position.
4. Fully depress SET button, and light pilot burner (adjust if necessary, refer to “Pilot Burner Adjustment”).
5. Allowpilottoburnapproximately½minutebeforereleasingSETbutton.Ifpilotamedoesnotremain
lit, repeat operation allowing longer period before releasing SET button.
6. TurnGASCOCKhandleto“ON”positionandturndialassemblytodesiredposition..Themainburner
should now ignite.
PROCEDUREFORADJUSTINGPILOT
1. Removepilotadjustmentcap.Adjustpilotkey,allowingametocompletelyenveloptheend(⅛”)ofthe
Thermocouple.
2. Adjustpilotburnerairshutter(ifprovided)toobtainasoftblueame.
2