SYMPTOM POSSIBLECAUSE SOLUTION
TROUBLESHOOTING GUIDE
DifcultyprimingtheTCCS
tea dispenser.
Adjusting rod on mixing valve
is turned in too far.
Openupthevalve1/4turn
counter clockwise.
Tea does not dispense from
faucet.
Water line is turned off.
Turn on the water line valve.
Onlywaterowsfromthe
faucet, no tea.
1.TeaconcentrateBIBisout
of product.
2.TheteaBIBlineiskinked.
3.TheteaBIBlineis
clogged.
4. The check valve in the tea
concentratelinemaybe
stuck closed.
5.Theadjustmentscrewmay
be turned in or closed.
1.Replacetheteaconcen-
trateBIB.
2. Trace the tea line and
straighten out kinked hose.
3.Blowouthosetoclean
blockage or replace with a
new hose.
4. Loosen the clamps and
remove the check valve.
Cleanorreplaceit.
5.Openthemixingvalveto
resumeproductow.
Faucetisdrippingconstantly. 1.Thefaucetseatcupmay
have solid particles that
are keeping the faucet
from sealing.
2.Theremaybeatearorcut
in the seat cup.
3.Waterpressuremaybe
too high.
1.Disassembleandclean
the seat cup (see cleaning
section).
2. Replacetheseatcup.
3.CallCURTISCAREfor
instructions on adjusting
the water regulator.
Finished tea is weak.
1. The mixing valve is out of
adjustment.
2. The product check valve
maybestuck.
1.Openthemixingvalveto
increase tea concentrate
ow.
2.Removeandcleanthe
checkvalve.Makesure
check valve is installed
withcorrectowdirection.