Owner's manual
10
SYMPTOM POSSIBLECAUSE SOLUTION
TROUBLESHOOTING GUIDE
Productowingfromthefau-
cetistoofoamyorbubbly.
1. The clamps at the check
valvemaynotbetight.
2. The clamp on the Scholle
connectormaybeloose.
3. Tea concentrate product
mayhaveairintheBIB.
4.TheO-ringontheScholle
connector is worn out.
1.Reconnecttubingand
tighten clamps.
2.Makesurethebarbed
endoftheSchollettingis
pushed in on the hose and
the clamp is tight.
3.TurntheBIBsothetting
faces upward and open
the faucet until all the
bubbles are released.
4.ReplacethewornO-ring
or install a new Scholle
connector.
DOs and DON’Ts
INSTALLATION
1.Doconnectdispensertoalteredwaterline.
2.Doushltersbeforeconnectingtodispenser.
3.Dosamplenisheddrinkbeforemakingad-
justments.
4.Domakeveryslightdrinkadjustmentsthen
sample.
5.Don’tforgettoushltersbeforeinstallation.
6.Don’tmakeanypressureregulatoradjust-
mentsondispenser(DoNOTattemptto
adjust the regulator. If a regulator adjustment
isrequiredcallCURTISCARE).
7.Don’tforgettogetsampleapprovalfromcus-
tomer.
OPERATION
1.Dofullyactivatefaucethandlewhendispens-
ing drinks.
2.Doclean&sanitizedispensingassembly
monthly.
3.Dokeepdispenserprimedwithconcentrateat
all times.
4.Doreloadimmediatelywhenoutofconcen-
trate.
5.Doushandcleanlinesregularly.
6.Don’tforgettoclean&sanitizefaucetseatcup
7.Dofollowallcleaningandsanitizingproce-
dures.Removeandstoreteaconcentrateif
dispenser will not be used for an extended
periodoftime(morethantwodays).