Owner's manual

1
NSF International requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the machine
can be moved for cleaning underneath.
2. Thisequipmentistobeinstalledwithadequatebackowprotectiontocomplywithapplicable
federal, state and local codes..
3. Waterpipeconnectionsandxturesdirectlyconnectedtoapotablewatersupplyshallbesized,
installed and maintained in accordance with federal, state, and local codes.
Important Safeguards/Symbols
Service Manual, Tea Concentrate Container Short
Thisapplianceisdesignedforcommercialuse.Anyservicingotherthancleaningandmaintenance
shouldbeperformedbyanauthorizedWilburCurtisservicecenter.
•DoNOTimmersetheunitinwateroranyotherliquid
•Nevercleanwithscouringpowders,bleachorharshchemicals.
Symbols:
WARNINGS – To help avoid personal injury Important Notes/Cautions
Sanitation Requirements
Curtis TCCS Units are Factory Pre-Set and Ready to Go… Right out of the Box.
Generallytherewillneverbeareasontochangefactorysettings.However,shouldyouneedto
makeslightadjustmentstomeetyourteaneeds,adjustmentinstructionsareprovidedlaterinthis
manual.
SystemRequirements:
•WaterSource30–90PSI(MinimumFlowRateof1GPM).Ifincomingwatersupplyisgreater
than90PSI,additionalregulationisrequiredtomeettherange.
•Waterpipeconnectionsandxturesdirectlyconnectedtoapotablewatersupplyshallbe
sized,installedandmaintainedinaccordancewithfederal,state,andlocalcodes.
SETUP STEPS
Theunitshouldbelevel(lefttorightandfronttoback),locatedonasolidcountertop.Connecta
waterlinefromthewaterltertotheTCCSserver.
NOTE:Sometypeofwaterltrationdevicemustbeusedtomaintainatrouble-freeop-
eration.(Inareaswithextremelyhardwater,wesuggestthatasedimentaryandtaste&
odorlterbeinstalled.)Thiswillprolongthelifeofyoursystemandenhanceteaquality.
INSTALLATION
1.Removedispenserfromcarton.
2.Runawaterlinetotheinletttingbehindthedispenser.Flushthenewwaterlinetoremovefor-
eign particles.
3.Connecta¼”aredexibleorcopperwaterlinetothemalettingontheback
of the dispenser.
4.Locatethewatersupplyvalvebehindtheunittoverifypositionisturnedon.
CAUTION:Werecommendedthatthewatersupplyvalve,behindunit,be
turnedoffduringnon-businesshours.
Wilbur Curtis Company, inC.
ModelsIncluded
•TCC2S
•TCC3S
NOTE:Watersource
pressure must be a
minimumof30PSI
pressure at all times
toinsurethequalityof
the of the product.
5.CleanouttheteaconcentratesystembeforeusingtheTCCSserver.UseaBag-in-
Boxstylecleaningsolutiontosimplifythecleaningprocedure.AcleanerlikeBev-
Cleanbeveragelinecleanercomesina3gallonbag-in-boxthatconnectsdirectlyto
yourbag-in-boxsystemforlinecleaning(http://bevclean.com).
a.Removethequickdisconnectfromtheteaconcentratebag.
b.PlacetheBIBcleanercontainernexttotheTCCSteadispenser.Pullthespout
fromthecleanerboxthroughthemarkedarea.Removethetravelcapfrom
spout.Don’tworryaboutcleanerspillingwhenthecapisremoved.Thecaphas
an internal seal.
OFF
ON
ISO 9001:2008 REGISTERED
WILBUR CURTIS CO., INC.
6913 West Acco Street
Montebello, CA 90640-5403
For the latest information go
to www.wilburcurtis.com
Tel: 800-421-6150
Fax: 323-837-2410

Summary of content (12 pages)