SYMPTOM POSSIBLECAUSE SOLUTION
TROUBLESHOOTING GUIDE
DifcultyprimingtheTCCtea
dispenser.
Adjusting rod on mixing valve is
turned in too far.
Openupthevalve1/4turn
counter clockwise.
Tea does not dispense from
faucet.
Water line is turned off.
Turn on water line valve.
Onlywaterowingfromfaucet,
no tea.
1.TeaconcentrateBIBisoutof
product.
2.TheteaBIBlineiskinked.
3.TheteaBIBlineisclogged.
4. The check valve in the tea
concentratelinemaybe
stuck closed.
5.Theadjustmentscrewmay
be turned in or closed.
1.Replacetheteaconcentrate
BIB.
2. Trace the tea line and
straighten out kinked hose.
3.Blowouthosetocleanblock-
age or replace with a new
hose.
4. Loosen the clamps and re-
movethecheckvalve.Clean
or replace it.
5.Openthemixingvalveto
resumeproductow.
Faucetisdrippingconstantly. 1.Thefaucetseatcupmayhave
hardened particles keeping
the faucet from sealing.
2.Theremaybeatearorcutin
the seat cup.
3.Waterpressuremaybetoo
high.
1.Disassembleandcleanthe
seat cup (see cleaning sec-
tion).
2. Replacetheseatcup.
______
3.CallCURTISCAREfor
instructions on adjusting the
water regulator.
Finished tea is weak.
1. The mixing valve is out of
adjustment.
2.Theproductcheckvalvemay
be stuck.
1.Openthemixingvalvetoin-
creaseteaconcentrateow.
2.Removeandcleanthecheck
valve.Makesurecheckvalve
isinstalledwithcorrectow
direction.