Manual
10
SYMPTOM POSSIBLECAUSE SOLUTION
TROUBLESHOOTING GUIDE
Productowingfromthefaucet
istoofoamyorbubbly.
1.Reconnecttubingandtighten
clamps.
2.Makesurethebarbedendof
theQCDttingispushedin
on the hose and the clamp is
tight.
3.TurntheBIBsothetting
faces upward and open the
faucet until all the bubbles
are released.
4.ReplacethewornO-ringor
installanewQCD.
DOs and DON’Ts
INSTALLATION
1.Doconnectdispensertoalteredwaterline.
2.Doushltersbeforeconnectingtodispenser.
3.Dosamplenisheddrinkbeforemakingad-
justments.
4.Domakeveryslightdrinkadjustmentsthen
sample.
5.Don’tforgettoushltersbeforeinstallation.
6.Don’tmakeanypressureregulatoradjust-
mentsondispenser(DoNOTattemptto
adjust the regulator. If a regulator adjustment
isrequiredcallCURTISCARE).
7.Don’tforgettogetsampleapprovalfromcus-
tomer.
OPERATION
1.Dofullyactivatefaucethandlewhendispens-
ing drinks.
2.Doclean&sanitizedispensingassembly
monthly.
3.Dokeepdispenserprimedwithconcentrateat
all times.
4.Doreloadimmediatelywhenoutofconcen-
trate.
5.Doushandcleanlinesregularly.
6.Don’tforgettoclean&sanitizefaucetseatcup
7.Dofollowallcleaningandsanitizingproce-
dures.Removeandstoreteaconcentrateif
dispenser will not be used for an extended
periodoftime(morethantwodays).
1. The clamps at the check
valvemaynotbetight.
2. TheclampontheQCD
connectormaybeloose.
3. Tea concentrate product
mayhaveairintheBIB.
4.TheO-ringontheQCDis
worn out.