User Manual
2
7. Carefullyliftthebagandsetthebagintothedispenser.
8. Rest tubing on top of the bag..
9. Replacethetopcover.
10. Dispensebeveragefromfaucetuntildarkerproductstartstoappear(~5seconds).
11. TheTCCNteadispenserisnowreadytoservetea.
3. Pullofftheshipping
cap that covers the
spout on the bag.
4. PlacetheQCDnextto
the spout.
5. SlideQCDsideways,
over the bag spout.
QCDsnapsinplace.
6. PushQCDplungerinto
bag spout until plunger
topisushwithtopof
QCD.A“click”willbe
heardwhenitisfully
inserted.
LOAD PRODUCT
1.PlaceateaconcentratebagonthecounternexttotheTCCNteadispenser.
2. RemovethetopcoverfromtheTCCNteadispenserandpulloutthehosewiththeQCD
bag connector.
c. Graspingthebagconnector(asshowninLoadProduct,step6),pushtheslidingprobeallthewayintothe
bagspout.A“click”willbeheardwhenitisfullyinserted.
d. Oncethecleaningsolutionboxisconnected,openthedispensingvalveonthedispenserandrunliquid
through the valve until the clear cleaner liquid is detected. The dispensing line is now clean.
e. Disengagethebagconnectorbysnappingtheconnectorprobeoutandremovetheconnectorfromthespout.
f. AttachateaconcentrateBIB.
g. Openthedispensingvalveondispenser.Allowliquidtoowuntilonlyteaows,noclearliquid.
WATER PRESSURE AND MIXING VALVE
Thetamper-proofindexmark(onthe’adjustmentknob-to-body’threadsofthepressureregulator)isafactorycalibrat-
ed,pressuresetting.Thepressureregulatorshouldrarelybechanged.Primary
taste/brixadjustmentsshouldbedoneviathemixingvalvebyturningtherod
andtastingthenishedproduct.98%ofavoradjustmentsshouldbedonein
this manner.
The purpose of the regulator is to provide uniform water pressure so the venturi-
stylemixingdevicecanproduceastableanduniformblendofconcentrateand
waterand,alsotoprotectthehydraulicsofthedispensingunitfrom“linepres-
sure”.Itisnottheprimaryadjustmentforthebrixlevel.Fromourtesting,ithas
beenshownthatexactPSIonthegagedoesnotdirectlycorrelatetoabrixlevel
from unit to unit and from installation location to installation location.
Secondarily,iftheprimaryadjustmentdoesn’tprovidetheidealbrixlevel,call
CurtisCareforinstructionsonhowtoadjusttheregulator.Asarule,verylittle
taste adjustment is achieved via the pressure regulator.
CAUTION: Do Not Exceed 25 psi (static). Equipmentfailureorleakagewill
result.