Instruction Manual
3
Cold Brew Lock . . . (Factory set to 15º)Presstoselect,<or>toselectdesiredsetting(CBL5,15orOFF), to set.
TheColdBrewLockfeatureallowsthebrewertobrewatthreedifferenttemperaturelevelsfromtheactualsetpoint.Therstsettingiswithin5degreesofset
point,nextiswithin15degreesofsetpoint,OFFiswithin30degreesofsetpointfortheReadytoBrewmessage,howeveritwillbrewatanytemperature.
ThisfeaturewilloperateafterinitializationtosettemperatureaftertherearstandbytoggleswitchisresettoON.
Master Reset PresstodisplayAreYouSure?Then<forYes,>forNo.Brewerfactorydefaultsarethenreset.
Service Call (Phone number Factory set to 1-800-000-0000X)Presstodisplaynumberandchangenumberor<tomoveplaceandEXtoexitwhen
completeThisnumberwillbedisplayedduringaHeatingsystemSENSORERRORorduringaWATERERROR.
Access Code (Factory set to 1-2-3-4)Presstodisplaynumberandchangenumber,(thenumbercanbechange1to4)or<tomoveplaceandextoexit
when complete.
Banner Name (Factory set to CURTIS)Presstodisplaylettersandchangelettersor<tomoveplaceandEXtoexitwhencomplete.Thisfeatureallows
upto14letterstobeprogrammedforcompanynameorregionalname.ProgrammingallblanksdisablesBannerName.
Warmers Auto OFF (Factory set to Disable)PresstoSelect.Press<or>tomovetodesiredtimeandthentoset.Timerisprogrammablefrom2to4
hoursinonehourincrementsorOFF.
P-Maintenance (Factory set to OFF)PresstoSelect,SetgallonsbrewedtoindicateP-Maintenance.Press<or>toadjustfromOffto3000gallons.
Presstoexit.
Beeper On/Off (Factory set to ON) PresstodisplayONorOFF.Pressingeither<or>togglesbetweenonandoff. to set.
Pulse Brew (Factory setting OFF)Presstoselect,<or>toselectOFForoneofvepulsepatterns(AtoE).
Guidelines for Pulse Brew:
Thisfeatureallowstuningofthecoffeeavor.ThepotlevelshouldalwaysbesetrstwiththisoptionOFF.Dependingonyourgrindproleandwatercondi-
tions,thevePulseBrewoptionshelp“tune”orchangethecoffeeavor.FilterPacktypecoffeestypicallyextractbetterwiththeAandBpulsesetting.Decaf-
feinatedcoffeestypicallyextractbetterwiththeBpulsesetting.High-YieldcoffeestypicallyextractbetterwiththeCpulsesetting.Ofcourse,anyoftheA,Bor
Csettingsmaybeusedtosuityourtasteprole.Therearetwoadditionalsettings(DandE)thatallowyoutomanuallysettheONTIMEpulsesandOFFTIME.
IfPulseBrewisselected(ON),ColdBrewLockissettoDelta1within5ºFofsetpointandColdBrewLockdisappearsfromthelistofprogramselec-
tions.WhenPulseBrewisON,Pre-infusiondisappearsfromthelistofprogramselections.
Display Brew Time (Factory set to ON). PresstodisplayONorOFF.Pressingeither<or>togglesbetweenonandoff.toset.Whenon,theDisplay
BrewTimefeatureallowsyoutoseetheremainingtimeinthebrewcyclecountingdown.
Drip-Out Mode (Factory set to 2 min)Presstoselect.Press>toincreasetime(toamaximumof5minutes)or<todecreasethetimeandturnOFF.
Timecountsupin5secondincrements.Press to set.
Display Messages (Factory set to ON) PresstoturnONorOFF.Themessagedisplayedis“RinseServerBeforeBrewing”.Thismessagewillalternate;
twosecondswithRinseServerBeforeBrewing,thenCurtisREADYTOBREWwillappearforsixseconds..
Language (Factory set to English) Pressing<or>togglesbetweenEnglishandFrench.Press to set.
Model Select Presstoselect,<or>toselectmodel.Theselectionsare:ALPHA-1,ALPHA-2,ALPHA-3/4/5,AirpotBrewer,Thermo-Alpha(fortheD60GT).
Presstoset.WhentheModelSelectfeatureischanged,allsettingsareresettothedefaultsofthenewlyselectedmodel.
Exit Presstoselect,exitsprogrammodeandreturnsunittooperation.
Warmer Temperature Control
Turn on brewer at the control panel ON/OFF button. Warmer button should be OFF (LED off). Press and hold desired WARMER button. Screen will display cur-
rent setting in % of power. Press < or > to increase or decrease power to warmer (50% to 100% in 10% increments). Press to set.
Tank Temperature Check
Turn on brewer at the control panel ON/OFF button. Press and hold 3 button (see illustration, page 2) for 5 seconds. Water Temperature will be displayed.
The temperature will not display while the unit is in the process reheating.
NOTE: Alpha 3GT ONLY; when checking tank temperature, rst make sure REAR warmer is ON (red LED on) and then press 3 for 5 seconds to display
tank temperature.
Brew Volume – Easy Access
Units produced beginning January 2008 can be easily adjusted from the front panel. Written into the software on the Alpha GT UCM, is a feature to access the
brew volume without entering the program mode.
The UCM must be on. To adjust the ALP1GT models, press and hold down the center, Select button 2 . The screen will read pressing < or >
will adjust the brew volume up or down, ± 20 oz, in 1 ounce increments.
On any multi-station Alpha (ALP2/3/4/5/6GT): Press the center Select button 2 twice, with the second press hold down the button for around ve [5] seconds.
The screen will display pressing < or > will adjust the brew volume up or down, ± 20 oz, in 1 ounce increments.
Vol. Adj. < -0 > Oz.
- Select +
Vol. Adj. < -0 > Oz.
- Select +
PROGRAM MENUS