Service manual
- 5 -
PROBLEM: WATER NOT FLOWING FROM SPRAYHEAD.
SOLUTION
POSSIBLECAUSE
Checkwaterlevelintank.Ifwaterisnotowingintothetank,re-
viewsteps1thru4,previouspage.
Checkthecontinuitybetweenterminals5Band4BwhentheBREW
switch is pressed. If there is no continuity, replace the switch.
Makesurethetimerisreceiving110to120volts.Youcanverify
thisbytakingareadingwithyourmeterattheendoftheYELLOW
wire on terminal 5B of the ON/OFF switch and at terminal 9 of the
timer. When the timer is activated by the brew switch, you should
read110to120voltsacrossterminals8 and 9 of the timer. The
REDwireonterminal8 supplies power to open the dump valve. If
no voltage is present, replace the timer.
If the timer works when the brew switch is pressed, then check the
dumpvalveusingavoltmeterontheterminals.Ifitshows110to
120voltsbutnowaterowsthroughthevalve,cleanoutthevalve
or replace the coil.
11.Waterlevelistoolow
in heating tank.
12.Defectivebrewswitch.
13.Defectivetimer.
14.Burnedoutdumpvalve
coil.
PROBLEM: WATER IN TANK DOES NOT GET HOT OR WATER TEMPERATURE TOO LOW
POSSIBLECAUSE
SOLUTION
10.Defectivethermostat.
Thermostat may be cutting off before the water temperature reaches
operatingtemperature.Donottrytoresetthethermostat.Replaceit.
GEMINI120A