Service manual

4
Tank Temperature Check
Turn on brewer at the control panel ON/OFF button. Press and hold button (see illustration, page 2) for 5 seconds. Water Temperature will
be displayed (temperature in heating tank).
Error Message
With the G3/Gold Cup Series brewers, there are three error messages that can appear on the screen to advise the user of a malfunction. If one
of these error messages appear, the brewer will lock up and stop functioning until the error is corrected. An error message will occur under the
following conditions:
1. Water level ll error or overow. This error message occurs when the inlet valve solenoid has been on for more than
10 minutes. This error message also occurs when the valve is relling the tank during a brew cycle for more than 1½
minutes.
2. Water temperature control system error. An open probe or a break in the temperature control circuit is detected.
3. This error message indicates there is an overheating problem. The sensor is reading that temperature in the heating
tank has risen above 210ºF.
Usually the screen will display a service call phone number. Once a malfunction is corrected, the error message must be
cleared. To reset the control panel and return to normal operation, press the button for 5 seconds.
(800) 000-000
Over Temp Error
(800) 000-000
Sensor Err
(800) 000-000
Water Level Err
P-Maintenance
Beeper On/Off
Exit
Quality Timer
Display Brew
Time
Cold Brew Lock (Factorysetto5ºF)
Presstoselect,<or>toselectdesiredsetting(CBL5,15orOFF), to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point.
The rst setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of
set point for the Ready to Brew message, however it will brew at any temperature.
Master Reset
PresstodisplayAreYouSure?Then<forYes,>forNo.WhenMasterResetisused,theallofthemenuselec-
tionsintheUCMreturntofactorydefaults.
Service Call(PhonenumberFactorysetto1-800-000-0000)
Presstodisplaynumberandchangenumberor<tomoveplaceandEXtoexitwhencomplete.Thisnumberwill
bedisplayedduringaHeatingsystemSENSORERRORorduringaWATERERROR.
Access Code(Factorysetto1-2-3-4)
Presstodisplaynumberandchangenumber,(thenumbercanbechanged1to4)or<tomoveplaceandextoexit
when complete.
Banner Name (FactorysettingreadsCURTIS)
Presstodisplaythecurrentbannerletters.Press<or>tomovecursor,presstoselectletters,orEXtoexit
whencomplete.Thisfeatureallowsupto14letterstobeprogrammed.ProgrammingallblanksdisablesBanner
Name.Whenabannerisset,thebannernameisdisplayedonlineoneandReadytoBrewisonthesecondline.
P-Maintenance (FactorysettoOFF)
PresstoSelect,SetgallonsbrewedtoindicateP-Maintenance.Press<or>toadjustfromOffto3000gallons.
Press to exit.
Beeper On/Off (FactorysettoON)
PresstodisplayONorOFF.Pressingeither<or>togglesbetweenonandoff. toset.WhenON,thisfeature
allowsyoutohearashortbeepeachtimeabuttonispressed.
Quality Timer (FactorysettoOFF)
PresstoSelect.Bypressing<or>buttons,youcanincreaseanddecreasetime.Settingrangeisfrom0to10
hoursin1hourincrements.Presstoset.Expiredtimeindicatedbyaudioalarmandashing“QualityTimer”.
Display Brew Time (FactorysettoON)
PresstoSelect.Pressing<or>togglesbetweenONandOFF.
Exit
Presstoselect,exitsprogrammodeandreturnsunittooperation.Pressing>returnsyoutoTeaRecipes.
Master Reset
Service Call
Cold Brew Lock
Access Code
Banner Name