Mini User Manual

9
6. Place the smoke ring in the smoke outlet hole in the back of the stove and secure it with the
three screws.
7. Replace the top plate on the stove.
A top cover can be bought as an accessory to cover the hole in the top plate of the stove if the
stove is connected to a rear smoke outlet.
General Information
When installing your WIKING wood-burning stove, you must ensure that all local regulations,
including those referring to national and European standards, are observed. It is always a
good idea to consult a chimney sweep before installing your stove, as it is he/she who must
ultimately approve the installation. Always follow the instructions of the manual carefully and
make sure that the installation is carried out by a qualied professional. WIKING packaging
material should always be handled in accordance with the local rules for waste handling.
Room Requirements
It must always be possible to deliver fresh combustion air to the room in which the wood-
burning stove is to be installed. A window that can be opened or an adjustable air valve is
considered to be sufcient. The adjustable air valve/air grate must not be blocked. Exhaust
fans running in the same room as where the stove is installed may cause problems.
Technical Data
If the wood-burning stove is to be placed on a oor made of combustible material, the area
around the stove must be covered with a non-combustible material. The oor construction
must also be able to withstand the weight of the stove and the chimney. The chimney’s weight
must be calculated in relation to dimension and height.
In the table below you’ll nd important information about your wood-burning stove.
Weight Dimension (h x w x d) Distance to furniture - in
front
Mini 2 with a base 73 kg 60.8 x 46.8 x 35.6 cm 100 cm
Mini 2 with short legs 73 kg 65.2 x 46.8 x 35.6 cm 100 cm
Mini 2 with long legs 74 kg 83.2 x 51.7 x 37.1 cm 100 cm
The stove is mainly made of sheet iron, with some items made of cast iron.
Nominal heat output: 4.5 kW according to EN norm
Flue gas temperature
EN 13240 measurement point:
236
o
C
Flue gas temperature
measured in the outlet socket:
283
o
C
Exhaust gas mass ow: 3,6 g/s
Gross and net efciency: 76% / 83%