Brochure

167167
RST –
Technical data
Wire preparation
Conductor cross-section
solid
fine-stranded
stranded
ultrasonically compressed
Conductor cross-section
fine-stranded
Insulation strip lengths and ferrules
all lengths indicated in mm
Screw connection:
Connector
13 – 18 mm
Splitter connector
max. 2 x 2.5 mm
2
!
Connector
6 – 10 mm
10 – 14 mm
Insulation strip length X =
Screwdriver
PZ1
Rated torque:
0.8 – 1.0 Nm
Screwdriver
PZ1
Rated torque:
0.5 – 0.7 Nm
all lengths indicated in mm
Screw connection:
Connector
13 –
18 m
m
Splitter connector
max. 2 x 1.5 mm
2
!
Connector
6 – 10 mm
10 – 14 mm
Connector
13 –
18 m
m
Connector
6 – 10 mm
10 – 14 mm
Insulation strip length X =
Insulation strip length X =
RST 4 / 5 pole
Spring clamp connection:
Crimp connection:
Fine-stranded and stranded
wires
Ferrules required!
Conductor cross-section
solid
fine-stranded
Ferrules according to DIN
stranded
Ferrules according to DIN
ultrasonically compressed
Connector Splitter connector
0.75 mm
2
8
8
8
8
2.5 mm
2
8
8
8
8
AWG 1218
8
1.0 mm
2
8
8
8
8
1.5 mm
2
8
8
8
8
4 mm
2
8
8
8
8
0.75 mm
2
7.0 +1
2.5 mm
2
7.0 +1
1.0 mm
2
7.0 +1
1.5 mm
2
7.0 +1
4 mm
2
7.0 +1
0.75 mm
2
8
8
8
8
2.5 mm
2
8
8
8
8
AWG 1218
8
1.0 mm
2
8
8
8
8
1.5 mm
2
8
8
8
8
4 mm
2
8
8
8
8
0.5 mm
2
14.5 + 1
12.0 + 1
46228-E0.5-10
0.75 mm
2
14.5 + 1
13.0 + 1
46228-E0.75-12
13.0 + 1
46228-E0.75-12
1 mm
2
14.5 + 1
13.0 + 1
46228-E1.0-12
13.0 + 1
46228-E1.0-12
1.5 mm
2
14.5 + 1
13.0 + 1
46228-E1.5-12
13.0 + 1
46228-E1.5-12
14.5 + 1
2.5 mm
2
14.5 + 1
14.5 + 1
Insulation strip length X =
Conductor cross-section
solid
fine-stranded
stranded
ultrasonically compressed
RST 2 /3 pole