Brochure
132
RST 20i2
RST 20i3
RST 25i3
RST 20i4
RST 20i5
RST 25i5
132
Distribution units
The highest level of flexibility!
Two housing variations are the basis:
a flat design with up to four slots, and
a high design with a total of up to eight
slots. Unused slots are closed during
production.
The distribution units are equipped
individually using M25 device
connectors.
These are available in various pole
configurations, with mechanical coding
and designs; they are customized using
2.5 mm
2
wires. Larger cross sections
are available upon request.
Overview of the standard
components:
Depending on the application, you can
choose among 15 codings.
Mechanically coded means that
only the matching male and female
connectors can be plugged together.
Thus you can be sure that your different
applications are clearly distinguished –
without having to rework incorrect
connections.
Compact and multi-distribution units
Flexibility according to the modular RST principle
The connector colors signal the
matching connections. The standard
power coding is an exception. Here
you can select between black and gray.
These are compatible with one another.
Spring clamp
Screw
Spring clamp
Screw
Screw ScrewCrimping
Screw
Spring clamp
Screw
Spring clamp
Screw
Spring clamp
Screw
Spring clamp
Screw
Spring clamp
Screw
Spring clamp
Screw
Crimping
Screw
Spring clamp
Screw
Spring clamp
Screw
Spring clamp
Screw
Female or Male
Protection class II
Pole designation
L, N
Coding:
black, gray
Female or Male
Power 250 V
Pole designation
L, N, U
Coding: black, gray
Female or Male
Single-phase
supply
(ENS)
Pole designation
L, N, U
Coding: concrete gray
Female or Male
Single-phase
infeed with
3-phase
monitoring
or 3-phase
infeed with
3-phase
monitoring
Pole designation
L, N, U, 1, 2
Coding: concrete gray
Female or Male
Power 250/400 V
Pole designation
U, 1, 2, 3
Coding:
black, gray
Female or Male
Power 250/400 V
Pole designation
U, N, 3, 2, 1
Coding: black, gray
Female or Male
LV, signals bus 50 V
Pole designation
1, 2
Coding: brown
Female or Male
Power 250/400 V
Pole designation
1, 2, U
Coding: green
Female or Male
LV, signals, bus, 50 V
Pole designation
1, 2, 3, 4, 5
Coding: brown
Female or Male
AS-i
Pole designation
+, –
Coding: pebble gray
Female or Male
LV, signals, bus, 50 V
Pole designation
1, 2, U
Coding: brown
Female or Male
AS-i / 24 V
Pole designation
1, 2, 3, 4
Coding:
brown
Female or Male
Power 250 V + dimming
Pole designation
L, N, U, D1, D2
Coding: turquoise
Female or Male
Switch. function 230 V
Pole designation
1, 2, 3
Coding: light blue
Female or Male
Switch. function 230 V
Pole designation
1, 2, 3, 4, 5
Coding: blue