SWITCH
AMP FUSE FUSE DISCONNECT DISCONNECT TWO DOOR
FREESTANDING & MODULAR
RATING CLIP CLASS HEIGHT X WIDTH Y FLOOR-MOUNT
MCS603R 30A No fuse 5.52 6.13
MCS603R 30A 30A-250V H, K, R 8.11 6.13
MCS603R 30A 30A-600V H, K, R 10.11 6.13
MCS603R 30A 30A-600V J 8.48 6.13
MCS606R 60A No fuse 5.52 6.13
MCS606R 60A 60A-250V H, K, R 7.86 6.13
MCS606R 60A 60A-600V H, K, R 10.38 6.13 For enclosures
MCS606R 60A 60A-600V J 8.36 6.13 that accept
MCS610R 100A No fuse 7.59 7.38 these devices,
MCS610R 100A 100A-250V H, K, R 11.85 7.38 see pages
MCS610R 100A 100A-600V H, K, R 13.85 7.38 F28-F29 &
MCS610R 100A 100A-600V J 10.60 7.38 F45-F46
MCS620R 200A No fuse 9.00 9.17
MCS620R 200A 200A-250V H, K, R 14.70 9.17
MCS620R 200A 200A-600V H, K, R 17.20 9.17
MCS620R 200A 200A-600V J 13.32 9.17
SIEMENS ITE MAX-FLEX
DISCONNECT SWITCHES FOR MAX-FLEX
OPERATORS
2 Door Floor-Mount NEMA 12, Heavy Duty Freestanding and Modular Enclosures, that are 24.00-inches deep, require a 48-inch Max-Flex
cable (minimum cable length).
Mechanisms and circuit breakers listed above will fit any 2 Door Floor-Mount NEMA 12, Heavy Duty Freestanding and Modular Enclosure.
Catalog numbers are for complete mechanisms which include flange-mounted handle, flexible operating cable, and circuit breaker operator. The last 3 digits
indicate cable length in inches.
24" deep enclosures require longer operating cables. Order components separately.
*Circuit breakers size includes required base mounting block.
COMPLETE OPERATOR CIRCUIT MAXIMUM CIRCUIT BREAKER CIRCUIT BREAKER
CIRCUIT BREAKER TYPE
MECHANISM FRAME SIZE AMP RATING HEIGHT X WIDTH Y
FHOE036 ED 125A 6.34 3.00 ED2. ED4. ED6. HED4. HED6
FHOE036 CED 125A 9.58 3.00 CED6
FHOF036 FD 250A 9.50 4.50 FXD6-A, FD6-A, HFD6, FXD6-ETJ, HHFD6, HHFXD6
FHOF036 CFD 250A 14.25 4.50 CFD6, CFD6-ETI
FHOJ036 JD 400A 11.00 7.50 JXD2, LXD6, JD6, HJD6, HHJD6, HHJXD6, JXD6-ETI
FHOJ036 CJD 400A 17.86 7.50 CJD6, CJD6-ETI
FHOJ036 LD 600A 11.00 7.50 LXD6, LD6, HLD6, HHLD6, HHLDX6, LXD6-ETI
FHOJ036 CLD 600A 17.86 7.50 CLD6, CLD6-ETI
FHOLM036 LMD 800A 16.00 9.00 LMD6, LMXD6, HLMD6, HLMXD6, LMXD6-ETI
FHON048 MD 800A 24.00 9.00 MD6, MXD6, HMD6, HMXD6, CMD6, MXD6-ETI, CMD6-ETI
FHON048 ND 1200A 24.00 9.00 ND6, NXD6, HND6, HNXD6, CND6
FHON048* PD 1600A 24.50 13.63 PD6, PXD6, HPD6, HPXD6, CPD6
FHON048* RD 2000A 24.50 13.63 RD6, RXD6, HRD6, HRXD6
SIEMENS ITE MAX-FLEX
CIRCUIT BREAKERS FOR MAX-FLEX
OPERATORS
†For Two Door Floor-Mount NEMA 12 “E” = 7.88 when “H” = 60.12
(Pages F28-F29 & F45-F46) “E” = 13.38 when “H” = 72.12
(Deduct 1.45 inches from "E" for FHON048 operator mechanism for MD, ND, PD, RD circuit breakers.)
For Heavy Duty Freestanding “E” = 11.88 when “H” = 72.12
and Modular Enclosures “E” = 17.38 when “H” = 84.12
(Pages F32 - F49) “E” = 20.38 when “H” = 90.12
(Deduct 1.45 inches from "E" for FHON048 operator mechanism for MD, ND, PD, RD circuit breakers.)
Space Occupied by Circuit Breaker
• The Siemens ITE Max-Flex
cable system allows the disconnect to be positioned independent from the flange-mounted handle mechanism.
• Refer to National Electrical Code
®
article 430-10(b) for wiring space “WB” required for line side conductors.
• Refer to Siemens ITE Max-Flex
installation instructions for limits on disconnect location when using 36" or 48" Max-Flex
cables.
• Space occupied by disconnect is determined by overall height “X”, width “Y”, wire bend space “WB” and location “G” as selected from right to left.
FLOOR-MOUNT FREESTANDING MODULAR SERIES ENCLOSURES
DISCONNECT SPACE OCCUPIED & AVAILABLE WIRING SPACE INFORMATION
For enclosures that accept
these devices,
(See pages F32-F49)