User guide

F53
www.hubbell-wiegmann.com
Data Subject To Change Without Notice
OETL-NF30-F 40A No fuse 4.45 3.91 0.56 9.53 15.53 13.53 19.53 22.53
OETL-NF60-F 80A No fuse 4.86 3.91 0.56 9.34 15.34 13.34 19.34 22.34
OETL-NF100-F 100A No fuse 4.86 4.91 0.56 8.78 14.78 12.78 18.78 21.78
OETL-NF175-F 175A No fuse 7.30 6.62 0.56 6.53 12.53 10.53 16.53 19.53
OETL-NF200-F 200A No fuse 7.36 7.41 0.56 6.53 12.53 10.53 16.53 19.53
OESA-F30J6-F 30A 30A-600V J 4.28 6.70 0.56 7.85 13.85 11.86 17.86 20.86
OESA-F60J6-F 60A 60A-600V J 4.28 6.39 0.56 7.85 13.85 11.86 17.86 20.86
OESA-F100J6-F 100A 100A-600V J 6.54 7.78 0.56 7.42 13.42 11.42 17.42 20.42
SWITCH AMP FUSE FUSE
SPACE OCCUPIED
WHEN WHEN WHEN WHEN WHEN
NUMBER RATING CLIP CLASS
FGK
H=60.12 H=72.12 H=72.12 H=84.12 H=90.12
WB WB WB WB WB
ABB CONTROLS DISCONNECT SWITCHES WITH FLANGE-MOUNTED OPERATORS
WIRE BEND SPACE “WB” ABOVE DISCONNECT
TWO DOOR FLOOR-MOUNT
FREESTANDING & M ODU LAR
(PAGES F28-F29 & F45-F46) ( P A GES F32-F49)
FHD-M 150A D 6.92 4.06 0.56 8.42 13.92 12.42 17.92 20.92
FHF-M 150A, 225A E/Q 5.98 4.55 0.56 6.97 12.47 10.97 16.47 19.47
FHF-M 225A F 7.44 4.55 0.56 6.97 12.47 10.97 16.47 19.47
FHJ-M 400A J 9.71 5.75 0.56 5.02 10.52 9.02 14.52 17.52
FHM-M 600A L 8.28 11.39 0.56 10.03 8.53 14.03 17.03
FHM-M 800A M 10.11 11.39 0.56 9.62 8.12 13.62 16.62
FHN-M 1200A N 12.18 11.39 0.56 9.81 12.81
AMP
FRAME TYPE
SPACE OCCUPIED
WHEN WHEN WHEN WHEN WHEN
MECHANISM
RATING
FGK
H=60.12 H=72.12 H=72.12 H=84.12 H=90.12
WB WB WB WB WB
ABB CONTROLS CIRCUIT BREAKERS WITH FLANGE-MOUNTED OPERATORS
WIRE BEND SPACE “WB” ABOVE DISCONNECT
TWO DOOR FLOOR-MOUNT
FREESTANDING & M ODU LAR
(PAGES F28-F29 & F45-F46) (PA GES F32-F49)
†For Two Door Floor-Mount NEMA 12 “E” = 7.88 when “H” = 60.12
(Pages F28-F29 & F45-F46) “E” = 13.38 when “H” = 72.12
For Heavy Duty Freestanding “E” = 11.88 when “H” = 72.12
and Modular Enclosures “E” = 17.38 when “H” = 84.12
(Pages F32- F49) “E” = 20.38 when “H” = 90.12
M40 15A-150A 5.00 4.62 0.56 7.25 13.25 11.25 17.25 20.25EHD, FD, FDB, FDC, HFD, HMCP
M50 70A-250A 9.75 4.88 0.56 6.81 12.81 10.81 16.81 19.81
JD, JDB, JDC, HJD, HMCP
M60 100A-400A 9.69 6.25 0.56 12.62 10.62 16.62 19.62KD, KDB, KDC, HKD, HMCP
ALLEN-BRADLEY TYPE 1494V OPERATORS FOR CIRCUIT BREAKERS
WIRE BEND SPACE “WB” ABOVE DISCONNECT
TWO DOOR FLOOR-MOUNT
FREESTANDING & M ODU LAR
(PAGES F28-F29 & F45-F46) ( P A GES F32-F49)
*The “G” dimension does not include space for auxiliary switches. See Allen-Bradley instructions for additional space required.
TYPE AMP CIRCUIT BREAKER TYPE
SPACE OCCUPIED
WHEN WHEN WHEN WHEN WHEN
NUMBER RATING FRAME SIZE
FG* K
H=60.12 H=72.12 H=72.12 H=84.12 H=90.12
WB WB WB WB WB
†For Two Door Floor-Mount NEMA 12 “E” = 7.88 when “H” = 60.12
(Pages F28-F29 & F45-F46) “E” = 13.38 when “H” = 72.12
For Heavy Duty Freestanding “E” = 11.88 when “H” = 72.12
and Modular Enclosures “E” = 17.38 when “H” = 84.12, except 400A or 600A switches
(Pages F32 - F49) “E” = 20.38 when “H” = 90.12, except 400A or 600A switches
“E” = 15.93 when “H” = 84.12, 400A and 600A switches only
“E” = 18.93 when “H” = 90.12, 400A and 600A switches only
FLOOR-MOUNT FREESTANDING MODULAR SERIES ENCLOSURES
DISCONNECT SPACE OCCUPIED & AVAILABLE WIRING SPACE INFORMATION