User guide

F51
N30 30A No fuse 4.62 6.50 0.99 5.31 11.31 9.31 15.31 18.31
NF30 30A 30A-250V H, K, R 6.50 6.50 0.99 5.31 11.31 9.31 15.31 18.31
NF30 30A 60A-250V H, K, R 7.25 6.50 0.99 5.31 11.31 9.31 15.31 18.31
NF30 30A 30A-600V H, K, R 9.25 6.50 0.99 5.31 11.31 9.31 15.31 18.31
NF30 30A 60A-600V H, K, R 9.75 6.50 0.99 5.31 11.31 9.31 15.31 18.31
NF30 30A 30A-600V J 6.50 6.50 0.99 5.31 11.31 9.31 15.31 18.31
NF30 30A 60A-600V J 6.62 6.50 0.99 5.31 11.31 9.31 15.31 18.31
N60 60A No fuse 4.62 6.50 0.99 4.62 10.62 8.62 14.62 17.62
NF60 60A 30A-600V H, K, R 10.38 6.50 0.99 4.62 10.62 8.62 14.62 17.62
NF60 60A 60A-250V H, K, R 8.38 6.50 0.99 4.62 10.62 8.62 14.62 17.62
NF60 60A 100A-250V H, K, R 10.88 6.50 0.99 4.62 10.62 8.62 14.62 17.62
NF60 60A 60A-600V H, K, R 10.88 6.50 0.99 4.62 10.62 8.62 14.62 17.62
NF60 60A 100A-600V H, K, R 12.88 6.62 0.99 4.62 10.62 8.62 14.62 17.62
NF60 60A 60A-600V J 7.75 6.50 0.99 4.62 10.62 8.62 14.62 17.62
NF60 60A 100A-600V J 9.75 6.50 0.99 4.62 10.62 8.62 14.62 17.62
N100 100A No fuse 4.62 7.25 0.99 8.75 6.75 12.75 15.75
NF100 100A 100A-250V H, K, R 11.38 7.38 0.99 8.75 6.75 12.75 15.75
NF100 100A 200A-250V H, K, R 12.25 7.62 0.99 8.75 6.75 12.75 15.75
NF100 100A 100A-600V H, K, R 13.38 7.50 0.99 8.75 6.75 12.75 15.75
NF100 100A 200A-600V H, K, R 14.75 7.75 0.99 8.75 6.75 12.75 15.75
NF100 100A 100A-600V J 10.12 7.38 0.99 8.75 6.75 12.75 15.75
NF100 100A 200A-600V J 10.88 7.50 0.99 8.75 6.75 12.75 15.75
N200 200A No fuse 7.12 10.38 1.06 7.12 5.12 11.12 14.12
NF200 200A 200A-250V H, K, R 15.00 10.38 1.06 7.12 5.12 11.12 14.12
NF200 200A 400A-250V H, K, R 16.56 10.75 1.06 7.12 5.12 11.12 14.12
NF200 200A 200A-600V H, K, R 17.56 10.38 1.06 7.12 5.12 11.12 14.12
NF200 200A 400A-600V H, K, R 19.56 11.00 1.06 7.12 5.12 11.12 14.12
NF200 200A 200A-600V J 13.69 10.38 1.06 7.12 5.12 11.12 14.12
NF200 200A 400A-600V J 15.00 10.62 1.06 7.12 5.12 11.12 14.12
TYPE AMP FUSE FUSE
SPACE OCCUPIED
WHEN WHEN WHEN WHEN WHEN
NUMBER RATING CLIP CLASS
FG* K
H=60.12 H=72.12 H=72.12 H=84.12 H=90.12
WB WB WB WB WB
ALLEN-BRADLEY TYPE 1494F DISCONNECT SWITCHES
WIRE BEND SPACE “WB” ABOVE DISCONNECT
TWO DOOR FLOOR-MOUNT
FREESTANDING & MODULAR
(PAGES F28-F29 & F45-F46) ( P AGES F32-F49)
N4/N40 150A 5.81 4.56 0.99 5.25 11.25 9.25 15.25 18.15EHD, FD, FDB, FDC, HFD, HMCP
N5/N55 225A
General Electric
8.81 4.75 0.99 4.44 10.44 8.44 14.44 17.44
TFK, THFK, TFC
N5/N50 250A 8.81 4.75 0.99 4.44 10.44 8.44 14.44 17.44
JD, JDB, JDC, HJD, HMCP
N5/N60 400A 8.81 5.88 0.99 10.50 8.50 14.50 17.50KD, KDB, KDC, HKD, HMCP
TYPE AMP CIRCUIT BREAKER TYPE
SPACE OCCUPIED
WHEN WHEN WHEN WHEN WHEN
NUMBER RATING FRAME SIZE
FG* K
H=60.12 H=72.12 H=72.12 H=84.12 H=90.12
WB WB WB WB WB
ALLEN-BRADLEY TYPE 1494D OPERATORS FOR CIRCUIT BREAKERS
WIRE BEND SPACE “WB” ABOVE DISCONNECT
TWO DOOR FLOOR-MOUNT
FREESTANDING & MODULAR
(PAGES F28-F29 & F45-F46) (PAGES F32-F49)
*The “G” dimension does not include space for auxiliary switches. See Allen-Bradley instructions for additional space required.
†For Two Door Floor-Mount NEMA 12 “E” = 5.88 when “H” = 60.12
(Pages F28-F29 & F45-F46) “E” = 11.38 when “H” = 72.12, except 200A switches
“E” = 10.06 when “H” = 72.12, 200A switches only
For Heavy Duty Freestanding “E” = 9.88 when “H” = 72.12, except 200A switch “E” = 8.56 when “H” = 72.12, 200A switch
and Modular Enclosures “E” = 15.38 when “H” = 84.12, except 200A switch “E” = 14.06 when “H” = 84.12, 200A switch
(Pages F32 - F49) “E” = 18.38 when “H” = 90.12, except 200A switch “E” = 17.06 when “H” = 90.12, 200A switch
FLOOR-MOUNT FREESTANDING MODULAR SERIES ENCLOSURES
DISCONNECT SPACE OCCUPIED & AVAILABLE WIRING SPACE INFORMATION
www.hubbell-wiegmann.com
Data Subject To Change Without Notice