User guide
ABN12, SDN12, SDN12PL, N412CD,
N412CSTD, N412CSSSTD, SN4 & SSN4X SERIES ENCLOSURES
DISCONNECT SPACE OCCUPIED & AVAILABLE WIRING SPACE INFORMATION
F20
www.hubbell-wiegmann.com
Data Subject To Change Without Notice
FRAME MAXIMUM CIRCUIT BREAKER CIRCUIT BREAKER
SIZE AMP RATING HEIGHT X WIDTH Y
E150 150A 6.31 4.12
SE150 150A 6.31 4.12
SF250 250A 10.12 4.12
SG600 600A 10.09 5.50
SK1200 1200A 15.50 8.25
GENERAL ELECTRIC CIRCUIT BREAKERS WITH SPECTRA FLEX
™
CABLE OPERATORS
For enclosures that
accept these devices,
see pages F2-F9.
For enclosures that
accept these devices,
see pages F10-F13.
FRAME BREAKER FLANGE-MOUNTING OPERATING
SIZE MECHANISM HANDLE** CABLE*
E150 SCOM1A SCH1 SC3L
SE150/SF250 SCOM1EF SCH1 SC3L
SG600 SCOM1G SCH1 SC3L
SK1200 SCOM1K SCH2K SC3H
* Operating cables are available in 3-foot to 10-foot lengths. (The number 3 in the catalog number denotes
3-foot cable.)
** Add “X” for NEMA 4 or 4X flange-mounted handle.
Space Occupied by Circuit Breaker
• The General Electric Spectra-Flex
™
system allows the circuit breaker to be positioned independent from
the flange-mounted handle mechanism.
• Refer to National Electrical Code
®
article 430-10(b) for wiring space "WB" required for line side conductors.
• Choose the operating cable length based on placement of the circuit breaker in the enclosure ensuring a 3"
minimum bending radius for the cable.
• Space occupied by circuit breaker is determined by overall circuit breaker size ("X" height and "Y" width)
plus "WB" wire bend space and location "G" as selected from right to left.
SWITCH
AMP FUSE FUSE DISCONNECT DISCONNECT
RATING CLIP CLASS HEIGHT X WIDTH Y
MCS603R 30A No fuse — 5.52 6.13
MCS603R 30A 30A-250V H, K, R 8.11 6.13
MCS603R 30A 30A-600V H, K, R 10.11 6.13
MCS603R 30A 30A-600V J 8.48 6.13
MCS606R 60A No fuse — 5.52 6.13
MCS606R 60A 60A-250V H, K, R 7.86 6.13
MCS606R 60A 60A-600V H, K, R 10.38 6.13
MCS606R 60A 60A-600V J 8.36 6.13
MCS610R 100A No fuse — 7.59 7.38
MCS610R 100A 100A-250V H, K, R 11.85 7.38
MCS610R 100A 100A-600V H, K, R 13.85 7.38
MCS610R 100A 100A-600V J 10.60 7.38
MCS620R 200A No fuse — 9.02 9.17
MCS620R 200A 200A-250V H, K, R 14.70 9.17
MCS620R 200A 200A-600V H, K, R 17.20 9.17
MCS620R 200A 200A-600V J 13.32 9.17
I-T-E DISCONNECT SWITCHES FOR MAX-FLEX
™
OPERATORS
For enclosures that
accept these devices,
see pages F2-F9.
For enclosures
that accept these
devices, see
pages F10-F13.
ABN12, SDN12, SDN12PL, N412CD, SN4 & SSN4X
N412CSTD, N412CSSSTD, SN4 & SSN4X WALL-MOUNTS
ABN12, SDN12, SDN12PL, N412CD, SN4 & SSN4X
N412CSTD, N412CSSSTD, SN4 & SSN4X WALL-MOUNTS