F1 Section F Index SDN12 Series NEMA 12 Flanged Single Door Disconnects ..........................................F3 SSN4X Series NEMA 4 Flanged Single Door Disconnects ........................................F12 WMOD Series NEMA 12 Modular Freestanding Disconnects ........................................F40 N412CD, N412CDSS, N412CDSSA Series ULTIMATE Flanged Single Door Disconnects ..........................................F6 ABN12 Series (1494F & 1494D) NEMA 12 Flanged Single Door Disconnects .......
F2 A B N 1 2 ( V, U , C ) , & S D N 1 2 , S D N 1 2 P L , N 4 1 2 C D , N 4 1 2 C S T D , S N 4 , S S N 4 X S E R I E S E N C L O S U R E S N E M A 1 2 F L A N G E D WA L L M O U N T D I S C O N N E C T S • General Electric Type STDA flange handles and variabledepth operating mechanisms for disconnect switches and circuit breakers. Also SPECTRAFLEX™ cable operators for circuit breakers • Siemens ITE Max-Flex™ flange-mount variable-depth operating handles for circuit breakers.
SDN12 & SDN12PL SERIES ENCLOSURES NEMA 12 FLANGED SINGLE DOOR DISCONNECT F3 Industry Standards UL 508, Types 12 & 13 CSA Certified, Type 12 NEMA/EEMAC Types 12 & 13 UL Files E64791 CSA File LL66078 F E AT U R E S - S P E C I F I C AT I O N S Construction • Bodies and doors fabricated from 14 gauge steel • Plasma welded seams • Rolled lip around all sides of enclosure opening excludes liquids and contaminants • Doors easily removed by pulling continuous hinge pin • Polyurethane poured-in-place gasket • Ex
F4 SDN12 & SDN12PL SERIES ENCLOSURES NEMA 12 FLANGED SINGLE DOOR DISCONNECT SDN12 & SDN12PL SERIES WALL-MOUNT DISCONNECTS CATALOG NUMBER BODY/DOOR WITH HANDLE WITHOUT HANDLE STEEL GAUGE ENCLOSURE SIZE H X W X D BACK PANEL CATALOG NUMBER* WHITE “G” BACK PANEL SIZE A X B SDN12202108PL SDN12202108 14/14 20.00x21.38x8.13 (508x543x206) NP2020 NP2020G 17.00x17.00 (432x432) SDN12242108PL SDN12242108 14/14 24.00x21.38x8.13 (610x543x206) NP2420 NP2420G 21.00x17.
F5 SDN12 & SDN12PL SERIES ENCLOSURES NEMA 12 FLANGED SINGLE DOOR DISCONNECT W 3.00 OMIT TWO MIDDLE STUDS IF W = LESS THAN 32.00" 3.00 D 2.00 Ø0.44 0.63 1.50 Y PANEL (Order Separately) 1.25 3.00 0.88 0.88 D-0.28 STIFFENER SEE Page F27 X X W-3.00 OMIT TWO MIDDLE STUDS IF H = LESS THAN 31.00" H-6.00 H A H-1.56 1.75 3.00 B 2.62 1.25 Y 0.63 DOOR STIFFENER IF H = 42.00" OR MORE 0.44 1.50 MOUNTING FEET SECTION Y-Y CONTINUOUS HINGE DOOR STIFFENER GASKET 0.63 0.88 Notes: 1.
F6 N 4 1 2 - C D N 4 1 2 - C D S S U LT I M AT E S E R I E S E N C L O S U R E S NEMA 412 FLANGED SINGLE DOOR DISCONNECT ( C A R B O N , 3 0 4 A N D 3 1 6 L S TA I N L E S S S T E E L ) Industry Standards UL 508, Types 12, 13, 4 & 4X CSA Certified, Type 12, 13, 4 & 4X NEMA/EEMAC Types 12, 13, 4 & 4X UL Files E64791 CSA File LL66078 F E AT U R E S - S P E C I F I C AT I O N S Construction • CD enclosure version bodies and doors fabricated from 14 gauge carbon steel • CDSS enclosure version bodies and door
N 4 1 2 - C D N 4 1 2 - C D S S U LT I M AT E S E R I E S E N C L O S U R E S NEMA 412 FLANGED SINGLE DOOR DISCONNECT F7 ( C A R B O N , 3 0 4 A N D 3 1 6 L S TA I N L E S S S T E E L ) N412CD ULTIMATE SERIES WALLMOUNT DISCONNECTS CARBON STEEL, PAINTED ANSI 61 POLYESTER POWDER CATALOG NUMBER BODY/DOOR STEEL GAUGE ENCLOSURE SIZE H X W X D BACK PANEL CATALOG NUMBER* WHITE “G” BACK PANEL SIZE A X B N412202208CD 14/14 20.00 x 22.00 x 8.00 (508 x 559 x 203) NP2020C NP2020CG 18.2 x 18.
F8 N412-CSTD & N412-CSSSTD SLOPE TOP DISCONNECT U LT I M AT E S E R I E S E N C L O S U R E S Industry Standards UL 508, Types 4, 4x, 12, & 13 CSA Certified, Types 4, 4x, 12, & 13 NEMA/EEMAC Types 4, 4x, 12, & 13 UL File E64791 N412242608CSSSTD CSA File LL66078 F E AT U R E S - S P E C I F I C AT I O N S Applications Hubbell Wiegmann N412CDTD & N412CSSSTD Ultimate Series Disconnects are designed to house and protect electrical and electronic components from harsh, dirty environments.
N 4 1 2 C S T D & N 4 1 2 C S S T D U LT I M AT E S E R I E S E N C L O S U R E S NEMA 4X SLOPE TOP SINGLE DOOR DISCONNECT F9 N 4 1 2 - C S T D U LT I M AT E S E R I E S E N C L O S U R E S N E M A 4 X S L O P E T O P S I N G L E D O O R D I S C O N N E C T CATALOG NUMBER BODY/DOOR STEEL GAUGE ENCLOSURE SIZE BACK PANEL CATALOG NUMBER* WHITE “G” H X W X D BACK PANEL SIZE A X B N412202208CSTD 14/14 20.00 x 22.00 x 8.00 (508 x 559 x 203) NP2020C NP2020CG 18.2 x 18.
F10 SN4 SERIES ENCLOSURES NEMA 4 FLANGED SINGLE DOOR DISCONNECT Industry Standards UL 508, Types 4, 12, & 13 CSA Certified, Types 4 & 12 NEMA/EEMAC Types 3, 4, 12, & 13 UL File E64791 SN4242108 CSA File LL66078 F E AT U R E S - S P E C I F I C AT I O N S Construction • Bodies and doors fabricated from 14 gauge steel • Plasma welded seams • Rolled lip around all sides of enclosure opening excludes liquids and contaminants • All exterior hardware is stainless steel • Stainless steel door clamps are provi
F11 SN4 SERIES ENCLOSURES NEMA 4 FLANGED SINGLE DOOR DISCONNECT W 3.00 OMIT TWO MIDDLE STUDS IF W = LESS THAN 32.00" 3.00 D 2.00 Ø0.44 0.63 1.50 Y PANEL (Order Separately) 1.25 0.88 3.00 TYP 0.88 D-0.28 STIFFENER SEE Page F27 X X W-3.13 OMIT TWO MIDDLE STUDS IF H = LESS THAN 31.00" H-6.00 H A H-1.63 1.75 B 2.62 1.25 Y 0.63 1.50 DOOR STIFFENER IF H = 42.00" OR MORE 0.44 MOUNTING FEET SECTION Y-Y CONTINUOUS HINGE DOOR STIFFENER GASKET 0.63 0.88 Notes: 2.50 1.
F12 SSN4X SERIES ENCLOSURES NEMA 4X FLANGED SINGLE DOOR DISCONNECT Industry Standards UL 508, Types 4, 4X, 12, & 13 CSA Certified, Types 4 & 12 NEMA/EEMAC Types 4, 4X, 12, & 13 UL File E64791 SSN4X242108 CSA File LL66078 F E AT U R E S - S P E C I F I C AT I O N S Construction • Bodies and doors fabricated from 14 gauge 304 stainless steel • Continuously welded seams ground smooth • Rolled lip around all sides of enclosure opening excludes liquids and contaminants • All exterior hardware is stainless s
F13 SSN4X SERIES ENCLOSURES NEMA 4X FLANGED SINGLE DOOR DISCONNECT W 3.00 OMIT TWO MIDDLE STUDS IF W = LESS THAN 32.00" 3.00 D 2.00 Ø0.44 0.63 1.50 Y PANEL (Order Separately) 1.25 0.88 3.00 TYP 0.88 D-0.28 STIFFENER SEE Page F27 X X W-3.13 OMIT TWO MIDDLE STUDS IF H = LESS THAN 31.00" H-6.00 H A H-1.63 1.75 B 2.62 1.25 Y 0.63 1.50 DOOR STIFFENER IF H = 42.00" OR MORE 0.44 MOUNTING FEET SECTION Y-Y CONTINUOUS HINGE DOOR STIFFENER GASKET 0.63 0.88 Notes: 2.50 1.
F14 ABN12, SDN12, SDN12PL, N412CD, N412CSTD, & N412CSSSTD SERIES ENCLOSURES NEMA 12 FLANGED SINGLE DOOR DISCONNECT DISCONNECT ORDERING INFORMATION When ordering wall-mounted disconnects from the various manufacturers, be sure to order all of the necessary items. Each company has a different system, so care is required. Order the following items from the disconnect manufacturer.
SN4 & SSN4X SERIES ENCLOSURES NEMA 4 FLANGED SINGLE DOOR DISCONNECT F15 DISCONNECT ORDERING INFORMATION When ordering wall-mounted disconnects from the various manufacturers, be sure to order all of the necessary items. Each company has a different system, so care is required. Order the following items from the disconnect manufacturer. Allen-Bradley When using a Bulletin 1494V disconnect switch, order: 1. A disconnect switch with operating mechanism (Bulletin 1494V) 2.
F16 ABN12, SDN12, SDN12PL, N412CD, N412CSTD, N412CSSSTD, SN4 & SSN4X SERIES ENCLOSURES D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N ALLEN-BRADLEY BULLETIN 1494V DISCONNECTS WIRE BEND SPACE “WB” ABOVE DISCONNECT ABN12, SDN12, SDN12PL, N412CD, SN4 & SSN4X WALL-MOUNTS N412CSTD & N412CSSSTD (PAGES F2-F9) (PAGES F10-F13) TYPE NUMBER AMP RATING FUSE CLIP FUSE CLASS F G* WHEN D=8.00 WB WHEN D=10.00 WB WHEN D=12 OR 16 WB WHEN D=8.
ABN12, SDN12, SDN12PL, N412CD, N412CSTD, N412CSSSTD, SN4 & SSN4X SERIES ENCLOSURES D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N F17 A B B C O N T R O L S D I S C O N N E C T S W I T C H E S W I T H F L A N G E - M O U N T E D O P E R AT O R S TYPE NUMBER AMP RATING FUSE CLIP FUSE CLASS K 2 F H D - M WIRE BEND SPACE “WB” ABOVE DISCONNECT ABN12, SDN12, SDN12PL, N412CD, SN4 & SSN4X WALL-MOUNTS N412CSTD & N412CSSSTD (PAGES F2-F9) (PAGES F10-F13)
F18 ABN12, SDN12, SDN12PL, N412CD, N412CSTD, N412CSSSTD, SN4 & SSN4X SERIES ENCLOSURES D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N E AT O N C U T L E R - H A M M E R C 3 7 1 C I R C U I T B R E A K E R O P E R AT O R S F O R C - H C I R C U I T B R E A K E R S WIRE BEND SPACE “WB” ABOVE DISCONNECT ABN12, SDN12, SDN12PL, N412CD, SN4 & SSN4X WALL-MOUNTS N412CSTD & N412CSSSTD (PAGES F2-F9) (PAGES F10-F13) TYPE NUMBER MAX AMP RATING FRAME TYPE F
ABN12, SDN12, SDN12PL, N412CD, N412CSTD, N412CSSSTD, SN4 & SSN4X SERIES ENCLOSURES D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N F19 G E N E R A L E L E C T R I C T Y P E S T D A O P E R AT O R S F O R D I S C O N N E C T S WIRE BEND SPACE “WB” ABOVE DISCONNECT ABN12, SDN12, SDN12PL, N412CD, SN4 & SSN4X WALL-MOUNTS N412CSTD, N412CSSSTD & SN4 (PAGES F2-F9) (PAGES F10-F13) MECHANISM AMP RATING FUSE CLIP FUSE CLASS G WHEN D=8.00 WB WHEN D=10.
F20 ABN12, SDN12, SDN12PL, N412CD, N412CSTD, N412CSSSTD, SN4 & SSN4X SERIES ENCLOSURES D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N G E N E R A L E L E C T R I C C I R C U I T B R E A K E R S W I T H S P E C T R A F L E X ™ C A B L E O P E R AT O R S FRAME SIZE MAXIMUM AMP RATING CIRCUIT BREAKER HEIGHT X CIRCUIT BREAKER WIDTH Y E150 150A 6.31 4.12 SE150 150A 6.31 4.12 SF250 250A 10.12 4.12 SG600 600A 10.09 5.
ABN12, SDN12, SDN12PL, N412CD, N412CSTD, N412CSSSTD, SN4 & SSN4X SERIES ENCLOSURES D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N F21 S I E M E N S I T E C I R C U I T B R E A K E R S F O R M A X - F L E X ™ O P E R AT O R S COMPLETE OPERATOR MECHANISM CIRCUIT BREAKER FRAME MAXIMUM AMP RATING CIRCUIT BREAKER CIRCUIT BREAKER HEIGHT X WIDTH Y CIRCUIT BREAKER TYPE FHOE036 ED 125A 6.34 3.00 ED2. ED4. ED6. HED4. HED6 FHOE036 CED 125A 9.
F22 ABN12, SDN12, SDN12PL, N412CD, N412CSTD, N412CSSSTD, SN4 & SSN4X SERIES ENCLOSURES D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N SCHNEIDER SQUARE D® C L A S S 9 4 2 2 VA R I A B L E D E P T H D I S C O N N E C T S WIRE BEND SPACE “WB” ABOVE DISCONNECT ABN12, SDN12, SDN12PL, N412CD, SN4 & SSN4X WALL-MOUNTS N412CSTD, N412CSSSTD & SN4 (PAGES F2-F9) (PAGES F10-F13) MECHANISM AMP RATING FUSE CLIP FUSE CLASS G WHEN D=8.00 WB WHEN D=10.
ABN12 FIXED DEPTH SERIES ENCLOSURES NEMA 12 FLANGED SINGLE DOOR DISCONNECT F23 Industry Standards UL 508, Types 12 & 13 CSA Certified, Type 12 NEMA/EEMAC Types 12 & 13 UL File E64791 ABN12242108 CSA File LL66078 F E AT U R E S - S P E C I F I C AT I O N S Applications Designed to house Allen-Bradley 1494F flange-mounted disconnect switches and Bulletin 1494D flange-mounted operators for circuit breakers. Provides protection from dust, dirt, oil and water.
F24 ABN12 FIXED DEPTH SERIES ENCLOSURES NEMA 12 FLANGED SINGLE DOOR DISCONNECT A B N 1 2 F I X E D D E P T H S E R I E S W A L L - M O U N T D I S C O N N E C T S ( C O N T. ) CATALOG NUMBER BODY/DOOR STEEL GAUGE ENCLOSURE SIZE H X W X D BACK PANEL CATALOG NUMBER* WHITE “G” BACK PANEL SIZE A X B ABN12362510 14/14 36.00x25.38x10.13 (914x645x257) NP3624 NP3624G 33.00x21.00 (838x533) ABN12363110 14/14 36.00x31.38x10.13 (914x797x257) NP3630 NP3630G 33.00x27.
ABN12 FIXED DEPTH SERIES ENCLOSURES NEMA 12 FLANGED SINGLE DOOR DISCONNECT Space Occupied by Disconnect E = 3.84 when Depth = 8.00 E = 6.75 when Depth = 10.00 E = 9.50 when Depth = 12.00 (Except enclosures for 200 amp switches) mension exceeds 17". er 40" high require rdware and enclosures rger require 3-point TOP HOLE IN R.H. FLANGE. or Stiffener Locations. E = 9.50 when Depth = 16.00 E = 10.50 when Depth = 12.00 (Except enclosures for 200 amp switches) E WB WB = Wiring Space 1.
F26 ABN12 /1494F & 1494D SERIES ENCLOSURES D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N ALLEN-BRADLEY 1494F DISCONNECT SWITCHES WIRE BEND SPACE “WB” ABOVE DISCONNECT ABN12 / 1494F (PAGES F20-22) FITS ENCLOSURE DEPTH 8.00 10.00 12.00 16.00 (203) (254) (305) (406) TYPE NUMBER AMP RATING FUSE CLIP FUSE CLASS SPACE OCCUPIED F G** WHEN E=3.84 WB WHEN E=6.75 WB WHEN E=9.50 WB • • • • N30 30A No fuse — 4.62 6.25 3.25 6.25 8.
F27 SDN12, SDN12 - PL, N412 - CD, N412 - CDSS, ABN12, SN4 & SSN4X SERIES D I S C O N N E C T E N C L O S U R E S S T I F F E N E R M AT R I X N 4 1 2 - C D U LT I M AT E S E R I E S W A L L - M O U N T D I S C O N N E C T S SDN12 & SDN12-PL SERIES WALL-MOUNT DISCONNECTS CATALOG NUMBER WITH HANDLE STIFFENER WITHOUT HANDLE DOOR BODY C ATA L O G N U M B E R N412202208CD BODY NO N412242208CD NO NO N412242608CD NO NO N412302608CD NO NO N412362608CD NO YES N412363208CD YES YES N412423212C
F28 WA X - U & WA C P X - U S E R I E S E N C L O S U R E S NEMA 12 FLOOR-MOUNT DISCONNECT Industry Standards UL 508, Type 12 CSA Certified, Type 12 NEMA/EEMAC Type 12 UL File E64791 WA60X4912U WA60CPX4912U CSA File LL66078 F E AT U R E S - S P E C I F I C AT I O N S Applications The Wiegmann universal cutout is used in large freestand and floorstand enclosures. Operator Adapter Kits are required in order to install the various manufacturers’ hardware.
F29 WA X - U & WA C P X - U S E R I E S E N C L O S U R E S NEMA 12 FLOOR-MOUNT DISCONNECT WAX-U AND WACPX-U SERIES FLOOR-MOUNT DISCONNECTS PROVISION CATALOG NUMBER RIGHT FLANGE MNT. CENTER POST MNT. BODY/DOOR STEEL GAUGE ENCLOSURE SIZE HXWXD BACKPANEL CATALOG NUMBER* WHITE “G” BACKPANEL SIZE A X B WA60X4912U WA60CPX4912U 10/10 60.13x49.75x12.13 (1527x1264x308) NPDD6048 NPDD6048G 56.00x44.00 (1422x1118) WA60X4918U — 10/10 60.13x49.75x18.13 (1527x1264x460) NPDD6048 NPDD6048G 56.00x44.
F30 WA X - U & WA C P X - U S E R I E S E N C L O S U R E S NEMA 12 FLOOR-MOUNT DISCONNECT Space Occupied by Disconnect 2.06 CL OF PANEL 2.06 WB WB PANEL PANEL E E TOP OF DISCONNECT CL TOP OF DISCONNECT TOP HOLE IN DISCONNECT HANDLE CL THIS SPACE OCCUPIED BY DISCONNECT SWITCH AND FUSE CLIP (IF USED) OR CIRCUIT BREAKER F G 2.
WA X - U & WA C P X - U S E R I E S E N C L O S U R E S NEMA 12 FLOOR-MOUNT DISCONNECT F31 DISCONNECT ORDERING INFORMATION When ordering wall-mounted disconnects from the various manufacturers, be sure to order all of the necessary items. Each company has a different system, so care is required. Order the following items from the disconnect manufacturer. Allen-Bradley Eaton Cutler-Hammer Siemens ITE Max-Flex™ When using a Bulletin 1494F flange-mounted disconnect switch, order: 1.
F32 WA X M - U S E R I E S E N C L O S U R E S N E M A 1 2 H E AV Y D U T Y F R E E S TA N D I N G D I S C O N N E C T Industry Standards UL 508, Type 12 CSA Certified, Type 12 NEMA/EEMAC Type 12 UL File E64791 WA72XM2718U CSA File LL66078 F E AT U R E S - S P E C I F I C AT I O N S Applications The Wiegmann universal cutout is used in large freestand and floorstand enclosures. Operator Adapter Kits are required in order to install the various manufacturers’ hardware.
F33 WA X M - U S E R I E S E N C L O S U R E S N E M A 1 2 H E AV Y D U T Y F R E E S TA N D I N G D I S C O N N E C T WA X M - U S E R I E S H E AV Y D U T Y S I N G L E D O O R D I S C O N N E C T S CATALOG NUMBER BODY/DOOR STEEL GAUGE ENCLOSURE SIZE H X W X D BACK PANEL SIZE A X B* WA 7 2 X M 2 7 1 8 U 10/10 72.13x27.50x18.13 (1832x699x460) 60.00x21.75 (1524x552) WA 7 2 X M 3 3 1 8 U 10/10 72.13x33.50x18.13 (1832x851x460) 60.00x27.75 (1524x705) WA 7 2 X M 3 9 1 8 U 10/10 72.13x39.50x18.
F34 WA X M - U S E R I E S E N C L O S U R E S N E M A 1 2 H E AV Y D U T Y F R E E S TA N D I N G D I S C O N N E C T WA X M - U S E R I E S H E AV Y D U T Y T W O D O O R D I S C O N N E C T S CATALOG NUMBER BODY/DOOR STEEL GAUGE ENCLOSURE SIZE H X W X D BACK PANEL SIZE A X B* WA 7 2 X M 5 3 1 8 U 10/10 72.13x53.75x18.13 (1832x1365x460) 60.00x48.00 (1524x1219) WA 7 2 X M 6 5 1 8 U 10/10 72.13x65.75x18.13 (1832x1670x460) 60.00x60.00 (1524x1524) WA 7 2 X M 7 7 1 8 U 10/10 72.13x77.75x18.
F35 WA X M - U S E R I E S E N C L O S U R E S N E M A 1 2 H E AV Y D U T Y F R E E S TA N D I N G D I S C O N N E C T WA X M - U S E R I E S H E AV Y D U T Y T H R E E D O O R D I S C O N N E C T S CATALOG NUMBER BODY/DOOR STEEL GAUGE ENCLOSURE SIZE H X W X D NO. OF PANELS BACK PANEL SIZE A X B* WA 7 2 X M 3 E Q 1 8 U 10/10 72.13x99.50x18.13 (1832x2527x460) 1 1 60.00x60.00 (1524x1524) 60.00x27.75 (1524x705) WA 7 2 X M 3 E W 1 8 U 10/10 72.13x117.50x18.13 (1832x2985x460) 1 1 60.00x72.
F36 WA X M - U S E R I E S E N C L O S U R E S N E M A 1 2 H E AV Y D U T Y F O U R D O O R F R E E S TA N D I N G D I S C O N N E C T WA X M - U S E R I E S H E AV Y D U T Y F O U R D O O R D I S C O N N E C T S CATALOG NUMBER BODY/DOOR STEEL GAUGE WA 8 4 X M 4 E W 1 8 U 10/10 ENCLOSURE SIZE H X W X D NO. OF PANELS 84.13x157.50x18.13 (2137x4001x461) BACK PANEL SIZE A X B* 2 72.00x72.00 (1829x1829) *Back panels are furnished with enclosures. W 36.50 2.56 36.50 1.88 X 2.56 36.50 2.62 1.
F37 WA X M - U S E R I E S E N C L O S U R E S N E M A 1 2 H E AV Y D U T Y F R E E S TA N D I N G F I V E D O O R D I S C O N N E C T WA X M - U S E R I E S H E AV Y D U T Y F I V E D O O R D I S C O N N E C T S CATALOG NUMBER BODY/DOOR STEEL GAUGE WA 8 4 X M 5 E W 1 8 U 10/10 ENCLOSURE SIZE H X W X D NO. OF PANELS BACK PANEL SIZE A X B* 2 1 84.13x196.75x18.13 (2137x4997x460) 72.00x72.00 (1829x1829) 72.00x33.75 (1829x857) *Back panels are furnished with enclosures. W 2.56 36.50 36.50 1.88 2.
F38 WA X M - U S E R I E S E N C L O S U R E S N E M A 1 2 H E AV Y D U T Y F R E E S TA N D I N G D I S C O N N E C T Space Occupied by Disconnect 4.06 PANEL WB E TOP OF DISCONNECT CL TOP HOLE IN DISCONNECT HANDLE THIS SPACE OCCUPIED BY DISCONNECT SWITCH AND FUSE CLIP (IF USED) OR CIRCUIT BREAKER G F 2.44 FOR 1 & 2 DOOR 2.94 FOR 3, 4 & 5 DOOR Note: 1. See pages F51-F60 for various brands of disconnects for “E”, “F”, “G” and “WB” dimensions. 2.
WA X M - U S E R I E S E N C L O S U R E S N E M A 1 2 H E AV Y D U T Y F R E E S TA N D I N G D I S C O N N E C T F39 DISCONNECT ORDERING INFORMATION When ordering wall-mounted disconnects from the various manufacturers, be sure to order all of the necessary items. Each company has a different system, so care is required. Order the following items from the disconnect manufacturer.
F40 WMOD SERIES ENCLOSURES N E M A 1 2 M O D U L A R F R E E S TA N D I N G D I S C O N N E C T Industry Standards UL 508, Type 12 CSA Certified, Type 12 NEMA/EEMAC Type 12 UL File E64791 WMOD72X4018U CSA File LL66078 F E AT U R E S - S P E C I F I C AT I O N S Applications Modular single-door and double-door Modular free-standing enclosures are designed to be bolted together in a variety of lengths and combinations to meet the customer’s specific application.
WMOD SERIES ENCLOSURES N E M A 1 2 M O D U L A R F R E E S TA N D I N G D I S C O N N E C T F41 WMOD SERIES SINGLE DOOR MODULAR FLANGE DISCONNECT (LEFT SIDE OPEN) CATALOG NUMBER BODY/DOOR STEEL GAUGE ENCLOSURE SIZE H X W X D BACK PANEL SIZE A X B* WMOD72X4018U 10/10 72.13x39.75x18.13 (1832x1010x460) 60.00x33.75 (1524x857) WMOD84X4018U 10/10 84.13x39.75x18.13 (2137x1010x460) 72.00x33.75 (1829x857) WMOD84X4024U 10/10 84.13x39.75x24.13 (2137x1010x613) 72.00x33.
F42 WMOD SERIES ENCLOSURES N E M A 1 2 M O D U L A R F R E E S TA N D I N G D I S C O N N E C T WMOD SERIES TWO DOOR MODULAR RIGHT FLANGE DISCONNECT (LEFT SIDE OPEN) CATALOG NUMBER BODY/DOOR STEEL GAUGE ENCLOSURE SIZE H X W X D BACK PANEL SIZE A X B* WMOD72X7818U 10/10 72.13x78.00x18.13 (1832x1981x460) 60.00x72.00 (1524x1829) WMOD84X7818U 10/10 84.13x78.00x18.13 (2137x1981x460) 72.00x72.00 (1829x1829) WMOD84X7824U 10/10 84.13x78.00x24.13 (2137x1981x613) 72.00x72.
F43 WMOD SERIES ENCLOSURES N E M A 1 2 M O D U L A R F R E E S TA N D I N G D I S C O N N E C T ACCESSORIES FOR MODULAR WMOD SERIES NEMA 12 FLANGE-MOUNTED DISCONNECTS CATALOG NUMBER BODY/DOOR STEEL GAUGE SIZE H X D (SEE DRAWING BELOW) WMOD7218EPT Formed end plate with gasket and bolts 72.13x18.13 (1832x460) WMOD7218FTPT Flat end plate with gasket and bolts 72.00x18.50 (1829x470) WMOD7218GK Gasket kit with gasket and bolts 72.00x18.
F44 WMOD SERIES ENCLOSURES N E M A 1 2 M O D U L A R F R E E S TA N D I N G D I S C O N N E C T DISCONNECT ORDERING INFORMATION When ordering wall-mounted disconnects from the various manufacturers, be sure to order all of the necessary items. Each company has a different system, so care is required. Order the following items from the disconnect manufacturer. Allen-Bradley Eaton Cutler-Hammer Siemens ITE Max-Flex™ When using a Bulletin 1494F flange-mounted disconnect switch, order: 1.
WA X - S S N 4 & WA C P X - S S N 4 E N C L O S U R E S NEMA 4X TWO DOOR FLOOR MOUNT DISCONNECT F45 Industry Standards UL 508, Types 4, 4X & 12 CSA Certified, Type 12 NEMA/EEMAC Types 4, 4X & 12 (UL 4 & 4X pending on CPX version) UL File E64791 WA72X7312SSN4 CSA File LL66078 F E AT U R E S - S P E C I F I C AT I O N S Applications Enclosure having the “WM” preferred cutout are sized for use with up to 200A disconnect switches and up to 400A circuit breakers unless otherwise specified.
F46 WA X - S S N 4 & WA C P X - S S N 4 E N C L O S U R E S NEMA 4X TWO DOOR FLOOR MOUNT DISCONNECT • Unless specified, the right door in considered to be the “master” door on the “Right Flange” mount enclosures and the left door is the “master” door on the “Center Post” mount enclosures.
F47 WA X - S S N 4 & WA C P X - S S N 4 E N C L O S U R E S NEMA 4X TWO DOOR FLOOR MOUNT DISCONNECT WAX-SSN4 W W/2 - 2.38 W/2 - 2.38 0.81 1.75 1.94 2.19 4.81 4.81 .69 0.88 CLEAR SPACE AVAILABLE 1.94 X H W/2 - 4.13 W/2 - 4.13 H - 1.38 2.06 0.88 3.50 1.75 D A 3.31 3.00 2.44 B 1.00 SECTION X-X BODY STIFFENER (NOT PROVIDED IF H OR W = 56.00" OR LESS) 1.94 .438 OPTIONAL PANEL 2.69 TYP. .69 PADLOCKING HANDLE CL H - 3.00 H/2 + 15.00" 1.50 2.06 REMOVABLE CENTER POST 15.
F48 WA X M - S S N 4 E N C L O S U R E S NEMA 4X TWO DOOR FLOOR MOUNT DISCONNECT Industry Standards UL 508, Type 3R, 4, 4X & 12 CSA Certified, Type 12 NEMA/EEMAC Type 3R, 4, 4X & 12 Single Door Rating Pending UL (Ref: 4 & 4X) UL File E64791 WA72XM2818SSN4 CSA File LL66078 F E AT U R E S - S P E C I F I C AT I O N S Applications Enclosure having the “WM” preferred cutout are sized for use with up to 200A disconnect switches and up to 400A circuit breakers unless otherwise specified.
WA X M - S S N 4 S E R I E S E N C L O S U R E S N E M A 4 X R I G H T F L A N G E S I N G L E & D O U B L E D O O R F R E E S TA N D I N G D I S C O N N E C T W A X M - S S N 4 E N C L O S U R E S N E M A 4 X O N E D O O R R I G H T F L A N G E F R E E S TA N D I N G H A N D L E D I S C O N N E C T CATALOG NUMBER SIZE H X W X D BACK PANEL SIZE A X B WA 7 2 X M 2 7 1 8 S S N 4 72.12x27.50x18.12 (1832x718x460) 60.00x21.75 (1524x552) WA 7 2 X M 3 3 1 8 S S N 4 72.12x33.50x18.12 (1832x870x460) 60.
F50 WA X - S S N 4 , WA X M - S S N 4 & WA C P X - S S N 4 S E R I E S E N C L O S U R E S N E M A 4 X R I G H T F L A N G E F R E E S TA N D I N G D I S C O N N E C T DISCONNECT ORDERING INFORMATION When ordering wall-mounted disconnects from the various manufacturers, be sure to order all of the necessary items. Each company has a different system, so care is required. Order the following items from the disconnect manufacturer.
F L O O R - M O U N T • F R E E S TA N D I N G • M O D U L A R S E R I E S E N C L O S U R E S D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N F51 ALLEN-BRADLEY TYPE 1494F DISCONNECT SWITCHES† WIRE BEND SPACE “WB” ABOVE DISCONNECT TWO DOOR FLOOR-MOUNT FREESTANDING & MODULAR (PAGES F28-F29 & F45-F46) (PAGES F32-F49) TYPE NUMBER AMP RATING FUSE CLIP SPACE OCCUPIED FUSE CLASS F — 4.62 6.50 0.99 G* K WHEN H=60.12 WB WHEN H=72.
F52 F L O O R - M O U N T • F R E E S TA N D I N G • M O D U L A R S E R I E S E N C L O S U R E S D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N ALLEN-BRADLEY TYPE 1494V DISCONNECT SWITCHES† WIRE BEND SPACE “WB” ABOVE DISCONNECT TWO DOOR FLOOR-MOUNT FREESTANDING & MODULAR (PAGES F28-F29 & F45-F46) (PAGES F32-F49) TYPE NUMBER AMP RATING FUSE CLIP SPACE OCCUPIED WHEN H=60.12 WB WHEN H=72.12 WB WHEN H=72.12 WB WHEN H=84.12 WB WHEN H=90.
F L O O R - M O U N T • F R E E S TA N D I N G • M O D U L A R S E R I E S E N C L O S U R E S D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N F53 A L L E N - B R A D L E Y T Y P E 1 4 9 4 V O P E R AT O R S F O R C I R C U I T B R E A K E R S † WIRE BEND SPACE “WB” ABOVE DISCONNECT TWO DOOR FLOOR-MOUNT FREESTANDING & MODULAR (PAGES F28-F29 & F45-F46) (PAGES F32-F49) TYPE NUMBER AMP RATING K WHEN H=60.12 WB WHEN H=72.
F54 F L O O R - M O U N T • F R E E S TA N D I N G • M O D U L A R S E R I E S E N C L O S U R E S D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N E AT O N C U T L E R - H A M M E R C 3 6 1 D I S C O N N E C T S W I T C H E S † WIRE BEND SPACE “WB” ABOVE DISCONNECT TWO DOOR FLOOR-MOUNT FREESTANDING & MODULAR (PAGES F28-F29 & F45-F46) (PAGES F32-F49) F G K WHEN H=60.12 WB 5.75 7.55 0.56 6.50 12.50 10.50 16.50 19.50 H, K, R 8.38 7.55 0.
F L O O R - M O U N T • F R E E S TA N D I N G • M O D U L A R S E R I E S E N C L O S U R E S D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N F55 EATON CUTLER-HAMMER FLEX SHAFT OPERATOR MECHANISMS ™ COMPLETE OPERATOR MECHANISM AMP RATING FRAME TYPE BREAKER HEIGHT BREAKER WIDTH F1S03 225A F Frame: EHD, FDB, FD, HFD 6.00 4.12 F1S03 150A F Frame: HMCP 6.00 4.12 F2S03 250A J Frame: JDB, JD, HJD, JDC 10.00 4.
F56 F L O O R - M O U N T • F R E E S TA N D I N G • M O D U L A R S E R I E S E N C L O S U R E S D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N G E N E R A L E L E C T R I C T Y P E S T D A D I S C O N N E C T S W I T C H O P E R AT O R S † WIRE BEND SPACE “WB” ABOVE DISCONNECT TWO DOOR FLOOR-MOUNT FREESTANDING & MODULAR (PAGES F28-F29 & F45-F46) (PAGES F32-F49) K WHEN H=60.12 WB TDOM1A 30A No fuse — 6.88 5.38 0.56 8.38 14.38 12.
F L O O R - M O U N T • F R E E S TA N D I N G • M O D U L A R S E R I E S E N C L O S U R E S D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N F57 G E N E R A L E L E C T R I C C I R C U I T B R E A K E R S W I T H S P E C T R A - F L E X C A B L E O P E R AT O R S † ™ FRAME SIZE MAXIMUM AMP RATING CIRCUIT BREAKER HEIGHT X CIRCUIT BREAKER WIDTH Y TWO DOOR FLOOR-MOUNT For enclosures that accept these devices,(See pages F28-F29 & F45F46) E150 1
F58 F L O O R - M O U N T • F R E E S TA N D I N G • M O D U L A R S E R I E S E N C L O S U R E S D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N S I E M E N S I T E M A X - F L E X D I S C O N N E C T S W I T C H E S F O R M A X - F L E X O P E R AT O R S † ™ SWITCH ™ AMP RATING FUSE CLIP FUSE CLASS DISCONNECT HEIGHT X DISCONNECT WIDTH Y TWO DOOR FLOOR-MOUNT FREESTANDING & MODULAR MCS603R 30A No fuse — 5.52 6.
F L O O R - M O U N T • F R E E S TA N D I N G • M O D U L A R S E R I E S E N C L O S U R E S D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N F59 SCHNEIDER SQUARE D® C L A S S 9 4 2 2 VA R I A B L E D E P T H D I S C O N N E C T S W I T C H E S † WIRE BEND SPACE “WB” ABOVE DISCONNECT TWO DOOR FLOOR-MOUNT FREESTANDING & MODULAR (PAGES F28-F29 & F45-F46) (PAGES F32-F49) TYPE NUMBER AMP RATING FUSE CLIP FUSE CLASS SPACE OCCUPIED WHEN H=60.
F60 F L O O R - M O U N T • F R E E S TA N D I N G • M O D U L A R S E R I E S E N C L O S U R E S D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N S CHNE I D E R S Q U A R E D ® CLASS 9422 DISCONNECT SWITCHES USED WITH CABLE MECHANISM 9422-CFT30 AND 9422-A1 HANDLE MECHANISM TYPE NUMBER AMP RATING FUSE CLIP FUSE CLASS DISCONNECT HEIGHT X DISCONNECT WIDTH Y TWO DOOR FLOOR-MOUNT FREESTANDING MODULAR TCN-30C 30A No fuse — 5.90 6.
ENCLOSURES N E M A 1 2 A D A P T E R P L AT E S WA21ABA F61 WA22BAP F E AT U R E S - S P E C I F I C AT I O N S O P E R AT O R A D A P T E R P L AT E S B L A N K A D A P T E R P L AT E S • Used on all Wiegmann disconnect enclosures with universal flange cutouts • An operator adapter plate is required to install a disconnect in all Wiegmann enclosures with a universal cutout on pages F28-F49.
NOTES www.hubbell-wiegmann.