User manual

WiebeTech
C o n fi g u r a t o r 3 . 0 U s e r s M a n u a l A 9 -0 0 0 - 0 0 2 7 R E V 1 . 0 - 7 -
3.4 RTX220-QRTab
Supported Product: RTX220-QR
3.4.1 Configuration PIN
This feature allows you to set a PIN to prevent
unauthorized configuration. The default PIN is 0000.
RTX220-QR only requires you to enter a PIN if a
different value has been set.
3.4.2 Buzzers
Place a check in the boxes to indicate which
warning/alarm buzzers you want to be activated.
3.4.2.1 System Warning Buzzer
This buzzer will sound when a drive reaches a default
temperature, or a temperature that you set (see
section 3.4.3). As a visual alert, the “system” LED will
glow amber when the temperature is reached.
3.4.2.2 System Alarm Buzzer
This buzzer will sound on 3 occasions:
When a drive reaches a default temperature or
the temperature that you set (see section 3.4.3).
When the enclosure reaches a default temperature or the temperature that you set (see section
3.4.3).
When the fan fails
As a visual alert, the “system” LED will glow red when any of these three situations occur.
3.4.2.3 RAID Warning Buzzer
This buzzer will sound when RTX220-QR is in degraded RAID mode (a drive has failed and is in need of
rebuild or the RAID is rebuilding). The “RAID” LED will glow amber if this occurs.
3.4.2.4 RAID Alarm Buzzer
This buzzer will sound when the RAID has failed or is
invalid. The “RAID” LED will glow red if this occurs.
3.4.3 Temperature Sliders
When your RTX220-QR reaches a certain temperature,
buzzers sound and the fan kicks on. You may want to
change these default temperatures according to your
environment. With these “sliders,” you can change the
default temperatures of the:
Enclosure fan kick-on
Enclosure Temp Alarm
Drive Temp Warning
Drive Temp Alarm