“?” Query
Input main select 0x98,
n l “+” l “-“ l
“r” l “R” l
“?”
Select input main =
PC or VIDEO or next available
Reset
Query
Main selected
“0”-Analog RGB(PC)
“1”-Digital DVI(PC)
“2”-BNC(PC)
“3”-CVBS
“4”-S_video
Select menu timeout 0x93,
n l “+” l “-“ l
“r” l “R” l
“?”
Select menu timeout =
Value / increment / decrement
Reset
Query
OSD menu timeout selected
“0”-20s
“1”-30s
“2”-50s
“3”-100s
OSD H position 0x90,
nnn l “+” l “-“ l
“r” l “R” l
“?”
Set OSD H position
Value / increment / decrement
Reset
Query
OSD Horizontal position
OSD H position 0x91,
nnn l “+” l “-“ l
“r” l “R” l
“?”
Set OSD H position
Value / increment / decrement
Reset
Query
OSD Horizontal position
Soft Power On / Off 0xc8
“0” l “1” l
“?”
Soft power
Off/on
Query
“0”-soft power off
“1”-soft power on
Query information
status
0xc9 read the status of information
“0”-serial number
“1”-s/w ver
“2”-temperature value
“3”-input satus
“4”-communication
“5”-backlight value
Query PCBA
number
0xcb, “1” Read PCBA number “nnnn” = PCBA number
Factory Recall 0xce Reset all parameters to default
Value.
“1”-successful
Graphic horizontal
Resolution enquiry
0xb7 Horizontal resolution (in
pixels)
In 3 digit hex number
“nnn” = Horizontal resolution
Graphic Vertical
Resolution enquiry
0xb8
Vertical resolution (in lines)
In 3 digit hex number
“nnn” = Vertical resolution
Graphic horizontal
Sync frequency
0xb9 Horizontal Sync frequency
(KHz)
In 3 digit hex number
“nnn” = Horizontal Sync
frequency