User`s manual
Issued Date
Revision Status
Title
Page No.
18 / 44
V2.2
2009-2-20
IDP2310UX
(AL23PUX)
1.3.4 Altitude
Non-operating : Up to 30,000 ft
Operating : Up to 10,000 ft
1.3.5 EMC
FCC Part 15 subpart B, Class A
CE(EMC)
-EN55022(EMI)
-EN55024(EMS)
MIC
VCCI Class A
IEC60945
1.3.6 Safety
CE & CB
EN60950-1
UL / cUL
UL60950-1
1.3.7 Certificate for ECDIS
EN61174(IEC61174)
1.3.8 Drip-proof
Front side is drip-proof. Test shall be done when the unit is mounted in a console.
Front bezel: IP64
NOTE: The unit is type approved according to EN60945(2002),4.4, equipment category b)Protected from the
weather (formerly class B)
1.4 OHTER SPECIFICATIONS
1.4.1 Reliability
MTBF (Mean Time Between Failures)
Standard calculated MTBF : 40,986h (MIL-HDBK-217F)
Ship calculated MTBF : 19,468h (MIL-HDBK-217F)
1.4.2 Maintainability
MTTR (Mean Time Between Repair)
IDP2310UX is defined as a Line Replaceable Unit (LRU) and the unit is designed to allow for an MTTR
less than 0.5 hour (30 minutes).