User`s manual
Issued Date
Revision Status
Title
Page No.
10 / 44
V2.2
2009-2-20
IDP2310UX
(AL23PUX)
Manual: Operator can select the input manually using control panel.
1.1.4 Controls of the Display
1.1.4.1 Remote Control via serial ports (JH Communication compatible)
There are serial ports on the back side of the IDP2310UX for remote control of the monitor by customer
application.
RS-422 port: Sub D, 15p, Female (for JH protocol)
RS-232/485 port: Sub D, 9p, Female (for JH protocol)
RS-485 port: Sub D, 9p, male as output (for Inter-Monitor Communication)
1.1.4.2 Control via OSD
Control block with the push buttons is available: Menu, Select, ◀ and ▶ . Settings are selected by the Menu
that guides you through the OSD menu.
Control block also has Volume for dimming brightness.
Control block also has LED indicators, refer to 1.1.5.
1.1.5 LED Indicator
Fault information in available by LED indicators
Normal : Green indicator
Soft Power Off: Amber indicator
No signal : Amber Blinking (every 1 second) indicator
System Fault : Red indicator
1.1.6 Power Supply Specification
1.1.6.1 Voltage range
Standard :100 –264Vac, 47~63Hz,1.0A at 230Vac
1.1.6.2 Power consumption
Normal
Max.
(100% Light output)
IDP2310UX 80 W 90W
1.1.6.3 Power variation protection
Unit will not be damaged when Voltage transients remain within value as defined in the applicable voltage
range
1.1.6.4 Over-temperature protection
When the internal temperature gets above than the warning level (65℃), the light output of the backlight is
half. And, LED as red color
When the internal temperature reaches above the critical Value (80℃), the light output of the backlight is
turned off. And, LED as red color
When the internal temperature gets below than the safe level (64℃), the light output of the backlight is
restored. And, LED recovers to green.
1.1.7 Connectors
1.1.7.1 Power connectors