User manual
Wide Bank 28 DS3 - Release 2.4 41
Retrieve Alarms
Retrieve Alarms
The following shows how to retrieve the current alarms for a facility.
RTRV-ALM-EQPT:tid:aid:ctag::[ntfcncde],[condtype];
RTRV-ALM-ENV:tid:aid:ctag::[ntfcncde],[condtype];
RTRV-ALM-E1:tid:aid:ctag::[ntfcncde],[condtype];
RTRV-ALM-T1:tid:aid:ctag::[ntfcncde],[condtype];
RTRV-ALM-T3:tid:aid:ctag::[ntfcncde],[condtype];
RTRV-ALM-ALL:tid:aid:ctag::[ntfcncde],[condtype]
Example Command
Retrieve ALL alarms RTRV-ALM-ALL;
Retrieve T3 major alarms RTRV-ALM-T3:tid::::MJ,;
Retrieve T1 #3 alarms RTRV-ALM-T1:tid:DS1-03;
Retrieve EQPT alarms RTRV-ALM-EQPT;
Facility AID
EQPT ALL
ENV ALL
T3 DS3-A, DS3-B, or ALL
T1 DS1-1 to DS1-28, or ALL
E1 E1-01 to E1-27, or ALL (see T3-E1 Configuration AIDs on page 8)
ALL ALL
Keyword Description
ntfcncde Severity or class of alarm, event or condition (optional). If omitted, the default
is ALL. Values are:
• CR – Critical Alarm
•MJ – Major Alarm
• MN – Minor Alarm
• CL – Condition Cleared
• NA – Not Alarmed
• NR – Not Reported
•ALL
condtype Type of condition or state to be retrieved (optional). If omitted, the value
defaults to ALL. To retrieve specific condition type values, see Alarm and
Event Message Parameters on page 43.