User manual
Wide Bank 28 DS3 - Release 2.4 39
PM Reports
PM Report Parameters
Keyword Description
locn Location (optional):
• NEND – near end and far end
monlev Monitor Level (optional) specifies the discriminating level for the requested
monitored parameter. The Wide Bank currently supports the following:
• 1-UP – report all performance statistics that do not have a value of zero
numrept The number of reports the user would like scheduled (optional). A value of zero
turns reports off. Otherwise, reports are sent every reporting interval and the
number of reports is decremented. Even if reporting is inhibited, the number
will continue to decrement. If the numrept value is omitted from the command,
the Wide Bank will report every reporting interval indefinitely until another
schedule command is issued.
• null – report all intervals
• 0 – no reports
• integer – number of reports
reptinvl Reporting Interval (optional). Specifies how often reports are to be generated
and sent:
•15-MIN
•1-HR
• 1-DAY
reptstatm Reporting Start Time (optional). Specifies the time when the reports should
start being generated. All selections will start reports at end of current reporting
interval.
• null
•0-0
•00-00
tmofst Time Offset (optional). The Wide Bank will accept the following values, but
the time offset will always be zero:
• null
• 0-1-0
tmper Time Period (optional):
•15-MIN
•1-HR
• 1-DAY}
Note: tmper must be equal to reptinvl or omitted.