User manual

32 Wide Bank 28 DS3 - Release 2.4
Diagnostics
Diagnostics
The following demonstrates how to perform self-test diagnostics.
CAUTION! FACILITIES MUST BE REMOVED FROM SERVICE BEFORE DIAGNOSTICS CAN
BE USED. DGN-T1 AND DGN-E1 WILL DISRUPT SERVICE ON THE SELECTED FACILITIES.
DGN-T3 AND DGN-ALL WILL INTERRUPT SERVICE ON ALL FACILITIES.
NOTE: A T3 can not actually be removed from service. The purpose of the RMV-T3
command is to allow the active T3 to be tested.
1. Place Facility Out of Service
RMV-T3:tid:aid:ctag;
RMV-T1:tid:aid:ctag;
RMV-E1:tid:aid:ctag;
Example: RMV-T3:tid:ALL:ctag;
Example: RMV-T1:tid:DS1-03:ctag;
2. Perform Diagnostic Test
DGN-T3:tid:aid:ctag;
DGN-T1:tid:aid:ctag;
DGN-E1:tid:aid:ctag;
DGN-ENV:tid:aid:ctag;
DGN-ALL:tid:ALL:ctag;
Example: DGN-T1:tid:DS1-03:ctag;
Response: tid 2002-01-18 11:51:58
M ctag COMPLD
"DS1-03:Pass,,"
;
Each diagnostic result is reported as Pass, Fail, or Not Present (unequipped).
3. Place Facility In Service
RST-T3:tid:aid:ctag;
RST-T1:tid:aid:ctag;
RST-E1:tid:aid:ctag;
Example: RST-T3:tid:ALL:ctag;
Example: RST-T1:tid:DS1-03:ctag;
AIDType AID
T3 ALL
T1 DS1-1 to DS1-28, or ALL
E1 E1-01 to E1-27, or ALL (see
T3-E1 Configuration AIDs on
page 8)
ENV FAN-A, FAN-B,or ALL
ALL ALL (tests all above AIDs)