User manual
Wide Bank 28 DS3 - Release 2.4 25
E1 Circuit Configuration
5. To Remove E1 From Service
CAUTION! REMOVING AN E1 WILL DISRUPT SERVICE.
RMV-E1:tid:aid:ctag;
Example: Place DS1 #3 out of service.
RMV-E1:tid:E1-03:ctag;
E1 Configuration Parameters
E1 facilities are hardcoded to HDB3 line code and no line buildout.
Keyword Description
AISF= Indicates whether failed signal from upstream should be replaced by AIS. Hard-
coded to Y.
CMDMDE= Indicates command execution mode. Hard-coded to FRCD. This means that
existing parameter settings may be overridden in order to execute the command.
DLCID= The E1 digital loop carrier system identifier. This is a string of ASCII
characters and has a maximum length of 32 characters.
FLMDE= Indicates the fault locate mode. Hard-coded to BOTH.
FMT= Indicates E1 digital signal format. Hard-coded to UNFR.
IDLE= Indicates the signal inserted for idle E1. Hard-coded to AIS.
LINECDE= Indicates E1 line code. E1 is always HDB3 (high density bipolar 3).
OMODE= Specifies what will be transmitted from the E1 output port. The Wide Bank
supports:
• NORM – Normal
• AIS – Alarm Indication Signal
RVRTFLAG= • UNLCKD – Unlocked. E1 will revert to home.
• LOCKED – Indicates if the E1 is locked onto the spare due to repeated
unsuccessful attempts at reverting to the working card (three attempts in 24
hours). The E1 will remain on the spare until this flag is cleared, the E1 card
is replaced, or the E1 is manually moved home (SW-TOWKG-E1).